Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2592 (Determination of flash and fire points - Cleveland open cup method)
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
ASTM D56 (Standard test method for flash point by tag closed cup tester)
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
other: ASTM D-3828
Deviations:
not specified
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Tag apparatus
Key result
Flash point:
> 250 °C
Atm. press.:
101.3 kPa
Remarks on result:
no flash point up to 100°C
Remarks:
Cleveland Open Cup Flash Point Results
Key result
Flash point:
94 °C
Atm. press.:
101.3 kPa
Remarks on result:
other:
Remarks:
TAG Closed Cup Flash Point Results
Key result
Flash point:
227 °C
Atm. press.:
101.3 kPa
Remarks on result:
other:
Remarks:
SETA Closed Cup Flash Point Results
Interpretation of results:
GHS criteria not met
Conclusions:
Under the conditions of the study, the flash point values for HES 10108 (Dow Corning By 16-122B) were -
Cleveland Open Cup Flash Point Results - > 250 °C
TAG Closed Cup Flash Point Results - 94 °C
SETA Closed Cup Flash Point Results - 227 °C
Executive summary:

Under the conditions of the study, the flash point values for HES 10108 (Dow Corning By 16-122B) were -

Cleveland Open Cup Flash Point Results - > 250 °C

TAG Closed Cup Flash Point Results - 94 °C

SETA Closed Cup Flash Point Results - 227 °C

Description of key information

Under the conditions of the study, the flash point values for HES 10108 (Dow Corning By 16-122B) were -

Cleveland Open Cup Flash Point Results - > 250 °C

TAG Closed Cup Flash Point Results - 94 °C

SETA Closed Cup Flash Point Results - 227 °C

Key value for chemical safety assessment

Additional information