Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09 February 2010 – 17 March 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
in accordance with GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO No., other: The International Organization for Standardization (ISO), ISO Guide 2719 (Determination of Flash Point – Pensky Martens Closed Cup method), 2002.
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM International, ASTM D 93 (Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester), December 10, 2002.
Deviations:
no
Remarks:
Note: this is not a ISO guideline, but ASTM guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: UN no. ST/SG/AC.10/11/Rev.4: Rec on the Transport of Dangerous Goods, Part III: Class Proc, Test Methods and Criteria Relating to Explosives of Class 3, Class 4, Division 5.1 and Class 9, Par 32.4.1(Non-Viscous Flammable Liquids), 2003
Deviations:
no
Remarks:
Note: this is not a ISO guideline, but UN guideline
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

1
Reference substance name:
Linseed oil, polymerized
EC Number:
614-114-9
Cas Number:
67746-08-1
Molecular formula:
Not applicable for UVCB
IUPAC Name:
Linseed oil, polymerized
Details on test material:
- Name of test material (as cited in study report): Standolized linseed oil
- Substance type: Hazy yellow/brown viscous liquid
- Physical state: liquid
- Analytical purity: treated as 100% pure
- Lot/batch No.: 09.317.013
- Expiration date of the lot/batch: 21 December 2010
- Stability under test conditions: stable
- Storage condition of test material: At room temperature in the dark
- Other: -

Results and discussion

Flash point
Key result
Remarks on result:
other: The test substance has a boiling temperature of approximately 328°C. No flammable vapour/air mixture was produced at temperatures below the boiling temperature. It was thus concluded that the test substance has no flash point.

Any other information on results incl. tables

It was visually observed that the test substance has a boiling temperature of approximately 328°C. No flammable vapour/air mixture was produced at temperatures below the boiling temperature of the test substance. From this, it was concluded that the test substance has no flash point.

Applicant's summary and conclusion

Conclusions:
The Pensky-Martens closed cup method was applied for the determination of the flash-point of Standolized linseed oil. No flash-point was observed below the boiling temperature of the test substance.