Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 March 2002 to 19 April 2002
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Version / remarks:
Cited as Directive 92/69/EEC, A.2
GLP compliance:
yes
Type of method:
differential scanning calorimetry
Specific details on test material used for the study:
DSC was used to determine the boiling point.The sample was heated from 20°C to 450°C at a rate of 20°C/min.
Key result
Decomposition:
yes
Remarks:
no boiling point could be determined
Decomp. temp.:
> 300 °C
Remarks on result:
not determinable
No boiling point could be determined since the sample was observed to have decomposed.  The DSC trace shows that the sample decomposed at a  temperature above 300°C.
Conclusions:
No boiling point could be determined since the sample was observed to have decomposed.
Executive summary:

No boiling point could be determined since the sample was observed to have decomposed.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 January 2002 to 26 April 2002
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Version / remarks:
Cited as Directive 92/69/EEC, A.2
GLP compliance:
yes
Type of method:
differential scanning calorimetry
Specific details on test material used for the study:
Determined using DSC. The main test performed at a rate of 5 K/min - two tests were performed (250-400°C and 200-400°C). The results from the two tests (328.5°C and 328.9°C) were averaged.
Key result
Boiling pt.:
328.7 °C
Atm. press.:
ca. 101.325 kPa
Decomposition:
no

The boiling point was performed at a rate of 5 K/min - two tests were performed (250-400°C and 200-400°C). The results from the two tests (328.5°C and 328.9°C) were averaged.

The boiling point of BIT was determined to be 328.7°C.

Conclusions:
The boiling point was performed at a rate of 5 K/min - two tests were performed (250-400°C and 200-400°C). The results from the two tests (328.5°C and 328.9°C) were averaged.
The boiling point of BIT was determined to be 328.7°C.
Executive summary:

The boiling point of BIT was determined to be 328.7°C.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
6 August 2002 to 04 June 2003
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Version / remarks:
Cited as Directive 92/69/EEC, A.2
GLP compliance:
yes
Type of method:
differential scanning calorimetry
Key result
Boiling pt.:
>= 339 - < 365 °C

The boiling point was determined using DSC by heating from 20°C to 400°C with a ramp of 10°C/min. Two determinations were made.

Boiling point range = 339°C to 365°C

Conclusions:
The boiling point was determined using DSC by heating from 20°C to 400°C with a ramp of 10°C/min. Two determinations were made.
Boiling point range = 339°C to 365°C
Executive summary:

Boiling point range = 339°C to 365°C

Description of key information

The boiling point was determined according to EU Method A.2 (Blake, 2002).

Key value for chemical safety assessment

Additional information

The substance decomposed above 300°C, therefore boiling point could not be determined.