Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
other:
Title:
Unnamed
Year:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Type of method:
electrical sensing zone (e.g. Coulter) method
Type of particle tested:
primary particle
Type of distribution:
counted distribution

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid

Results and discussion

Mass median aerodynamic diameter:
ca. 82.06 µm
Particle sizeopen allclose all
Key result
Percentile:
other:
Mean:
> 200 µm
Remarks on result:
other:
Key result
Percentile:
other:
Mean:
< 2 µm
Remarks on result:
other:

Applicant's summary and conclusion