Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1.2. - 6.2.2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Version / remarks:
published in O.J. L 142, 2008
Deviations:
yes
Remarks:
see Any other information...
GLP compliance:
yes (incl. QA statement)
Contact with:
powdered cellulose
Duration of test (contact time):
266 s
Sample tested:
reference mixture as specified
Remarks:
60% barium nitrate with cellulose
Parameter:
maximum burning rate
Result:
1.1 mm/s
Sample tested:
test mixture as specified
Remarks:
10% test substance with cellulose
Parameter:
burning rate
Result:
0.75 mm/s
Key result
Sample tested:
test mixture as specified
Remarks:
10% test substance with cellulose
Parameter:
maximum burning rate
Result:
0.78 mm/s
Interpretation of results:
GHS criteria not met
Conclusions:
Based on results obtained from train test, it is obvious that test substance, Reactive Yellow 85, shouldn´t be considered as a substance with oxidizing properties.
Executive summary:

The oxidizing properties of test substance, Reactive Yellow 85, were determined. The procedure was performed according to the Method A.17 Oxidizing properties (Solids),Council Regulation (EC) No.440/2008, published in O.J. L 142, 2008.

 

Based on results obtained from train test, it is obvious that test substance, Reactive Yellow 85, shouldn´t be considered as a substance with oxidizing properties.

 

Description of key information

Based on results obtained from train test, it is obvious that test substance, Reactive Yellow 85, shouldn´t be considered as a substance with oxidizing properties.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification