Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
03 February 2016 - 06 July 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Qualifier:
according to
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
effusion method: isothermal thermogravimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material (as cited in study reports): JNJ-17299412-AAA (T001599)
- Physical state: solid (powder)
- Appearance: white powder
Specific details on test material used for the study:
- Batch n°: I15HB2951
- Analytical purity: 100.2% (Based on base titration assay)
- Expiration date: 09 August 2017
- Storage condition: at room temperature

Results and discussion

Vapour pressureopen allclose all
Key result
Temp.:
20 °C
Vapour pressure:
< 0.002 Pa
Key result
Temp.:
25 °C
Vapour pressure:
< 0.007 Pa

Any other information on results incl. tables

Reference substances

Validation of the method is performed at least once every year (project 512551). Each reference substance was measured in duplicate by TGA using a temperature program that was specific for the substance. Plots of log vT obtained at elevated temperatures and 1/T were inter- or extrapolated to determine the log vTvalues at 20°C (log vT,20). The log vT,20 values were plotted against the logarithm of the vapour pressure at 20°C in Pascal units (log PT,20). Linear regression analysis using the least squares method yielded an equation of log PT,20= 1.34 log vT,20+ 4.96. The coefficient of correlation (r) was > 0.99. The constants c and d specific for the experimental arrangement were 1.34 and 4.96, respectively.

Results

In the range of 80°C and 110°C (before melting) and in the range of 120°C to 150°C (above melting) a log p versus 1/T curve for the test substance could not be determined since the coefficient of correlation (r) was < 0.99.

Since no accurate vapour pressure could be calculated from the obtained results, the weight losses were compared with the results of hexachlorobenzene. Since the weight loss of the test item was lower than the weight loss of the reference compound the vapour pressure of the test item is considered to be below the vapour pressure of hexachlorobenzene.

The results for the vapour pressure of the test item at 20°C and 25°C are:

 Temperature (°C)  PT (Pa)  PT (mm Hg)
 20  < 1.5 × 10 -3  < 1.1 × 10-5
 25   < 6.7 × 10-3    < 5.0 × 10-5

 

 

 

Applicant's summary and conclusion

Conclusions:
The isothermal TGA effusion method was applied for the determination of the vapour pressure of JNJ-17299412-AAA (T001599).
The vapour pressure of the test item was < 1.5E-3 Pa (or < 1.1E-5 mmHg) at 20°C (293K) and < 6.7E-3 Pa (or < 5.0E-5 mmHg) at 25°C (298K).