Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted on15 March 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
not specified
GLP compliance:
no
Remarks:
Study was not conducted under a specific Good Laboratory Practices (GLP) program, this study was conducted following the principles of GLP by experienced and trained personnel using calibrated standards and instrumentation. Relevant SOPs were followed
Type of method:
flask method
Specific details on test material used for the study:
Lot/Batch number: 1004R18708
Key result
Water solubility:
> 0.239 - < 0.34 g/L
Conc. based on:
test mat.
Loading of aqueous phase:
1 g/L
Incubation duration:
> 1 - < 3 d
Temp.:
30 °C
pH:
> 5.4 - < 5.6
Details on results:
The aqueous concentrations determined for RD14156 in the equilibrated samples are shown in Table1. Only determinations 3, 4, 5 and 6 are within 15% of the average value, determinations 1 and 2 are outside. The amount of sample initially added to the tubes is also indicated. The averaged water solubility for RD14156 is [0.26 g/L].

The aqueous concentrations determined for RD14156 in the equilibrated samples are shown in Table 1. Only determinations 3, 4, 5 and 6 are within 15% of the average value, determinations 1 and 2 are outside. The amount of sample initially added to the tubes is also indicated. The averaged water solubility for RD14156 is [0.26 g/L].

Table 1. RD1416 water solubility.

 Sample #  Sample added (g/L)  Equilibration time (days)  Measured conc. (g/L)  Percent of average
 1  1.136  1  0.327  128
 2  1.110  1  0.340  133
 3  1.068  2  0.273  107
 4  1.034  2  0.270  106
 5  1.142  3  0.241  94
 6  1.064  3  0.239  93
 Average of samples 3 - 6        0.256  -
Conclusions:
The RD14156 material under test was analyzed per guidelines as set forth in OECD 105, water solubility, shake flask method. The water solubility is 0.26 [g/L].
Executive summary:

The RD14156 material under test was analyzed per guidelines as set forth in OECD 105, water solubility, shake flask method. size exclusion chromatography (SEC) was the method of choice to determine concentrations of test material in solutions. The water solubility is 0.26 [g/L].

Description of key information

The RD 14156 material under test was analyzed in accordance with the guideline set forth in OECD 105, water solubility, shake flask method. the water solubility was 0.26 g/L

Key value for chemical safety assessment

Water solubility:
0.26 g/L
at the temperature of:
30 °C

Additional information