Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Auto-ignition temperature:
400 °C
Atm. press.:
>= 99 000 - <= 102 000 Pa

 Table 1

Atmospheric pressure: 99000 to 102000 Pa

Test temperature (°C)

Test quantity (mg)

Time (s)

Observation

 

 

 

 

400

70

6

Orange flame

350

70

>300

No ignition

350

1000

>300

No ignition

376

70

>300

No ignition

376

1000

>300

No ignition

388

70

>300

No ignition

388

1000

>300

No ignition

392

70

>300

No ignition

392

1000

>300

No ignition

396

70

>300

No ignition

396

1000

>300

No ignition

398

70

>300

No ignition

398

1000

>300

No ignition

398

100

>300

No ignition

398

200

>300

No ignition

398

500

>300

No ignition

398

70

>300

No ignition

398

70

>300

No ignition

398

70

>300

No ignition

398

70

>300

No ignition

398

70

>300

No ignition

 

 

 

 

 

Description of key information

400 °C at 99'000 - 102'000 Pa (EU A.15)

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
400 °C

Additional information