Registration Dossier

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: reliable, well-documented GLP study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report Date:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Version / remarks:
(Grewer-oven)
Principles of method if other than guideline:
The Grewer oven was used to comply also with the CLP-regulation (screening test for self-heating properties; VDI-Richtlinie 226)
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Relative self-ignition temperature (solids)
Remarks on result:
other:

Any other information on results incl. tables

No self-heating was observed according to the CLP regulation (EC) no 1272/2008 and no self-ignition temperature was observed up to the melting point according to the testing guideline for auto-flammability (solids - determination of relative self-ignition temperature) in the sense of the European Commission Regulation (EC) No. 440/2008.

Applicant's summary and conclusion