Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
surface tension
Type of information:
other:
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
The test material decomposes at elevated temperatures generating toxic H2S fumes. Due to the toxic nature of the degradation material, the method could not be run in the apparatus outside a ventillation hood. Inside a ventillation hood, the test apparatus is unable to equilibrate, which is a testing protocol requirement.
Data waiving:
study technically not feasible
Justification for data waiving:
other:
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM D1331
Deviations:
no
Principles of method if other than guideline:
None
GLP compliance:
no
Type of method:
ring method

Test material

Constituent 1
Reference substance name:
Phosphorodithioic acid, mixed O,O-bis(sec-Bu and 1,3-dimethylbutyl) esters, zinc salts
EC Number:
272-238-5
EC Name:
Phosphorodithioic acid, mixed O,O-bis(sec-Bu and 1,3-dimethylbutyl) esters, zinc salts
Cas Number:
68784-31-6
Molecular formula:
C(16-24) H(36-42) O4 P2 S4 Zn
IUPAC Name:
Phosphorodithioic acid, mixed O,O-bis(sec-Bu and 1,3-dimethylbutyl) esters, zinc salts
Constituent 2
Reference substance name:
OLOA 262
IUPAC Name:
OLOA 262
Details on test material:
- OLOA 262
- Expiration date: December 31, 2010

Results and discussion

Surface tension
Remarks on result:
other: Test method could not be run in a ventillation hood because the apparatus would be unable to equilibrate.

Any other information on results incl. tables

None

Applicant's summary and conclusion

Conclusions:
Test apparatus could not be equilibrated in ventillation hood, which was required due to the toxic nature of the decomposition material.
Executive summary:

Test apparatus could not be equilibrated in ventillation hood, which was required due to the toxic nature of the decomposition material.