Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27 May 2014 - 28 May 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: According to the method OECD 114 with GLP study.
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
16.1
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
7.37

The results of viscosity determination at 20°C

 

Test No.

 

Test temperature

 

 

Flow time

 

t

The difference in flow time of two consecutive measurements

 

Viscosity

 

ν

The difference between any and average viscosity

t

 

[°C]

[ s ]

[%]

[mm2/s]

[% ]

1

20.00

553.25

0.10

16.066

0.05

2

20.00

552.70

16.050

0.05

Average

16.1

-

The results of viscosity determination at 40°C

Test No.

Test temperature

Flow time

 

t

The difference in flow time of two consecutive measurements

Viscosity

 

ν

The difference between any and average viscosity

t

[°C]

[ s ]

[%]

[mm2/s]

[% ]

1

40.00

731.25

0.03

7.371

0.01

2

40.00

731.04

7.369

0.011

Average

7.37

-

Conclusions:
The determined average kinematic viscosity of the tested material at 20 °C temperature is 16.1 mm2/s.
The determined average kinematic viscosity of the tested material at 40 °C temperature is 7.37 mm2/s.
Executive summary:

The viscosity of test item was calculated using capillary metyhod in accordance with OECD Guideline 114. The determined average kinematic viscosity of the tested material at 20 °C and 40ºC temperature was 16.1 mm2/s and 7.37 mm2/s respectively.

Description of key information

Key study. OECD 114. Capillary method. Viscosity os test item at 20ºC was 16.1 mm2/s

Key value for chemical safety assessment

Viscosity:
16.1 mm²/s (static)
at the temperature of:
20 °C

Additional information

Key study: The viscosity of test item was calculated using capillary metyhod in accordance with OECD Guideline 114. The determined average kinematic viscosity of the tested material at 20 °C and 40ºC temperature was 16.1 mm2/s and 7.37 mm2/s respectively.