Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ASTM E659 (Standard test method for autoignition temperature of liquid chemicals)
Specific details on test material used for the study:
Lot #JBKF0002R
Key result
Auto-ignition temperature:
ca. 475 - 480 °C
Atm. press.:
ca. 101 325 Pa

Results:

 Sample size (ml)  Flask temp., °C  Ignition Yes/No  Ingnition delay, sec  Comments
 0.25  400  No    No flame

 0.25

 420  No    No flame
 0.25  450  No    No flame
  0.25  460  No    No flame
  0.25  470  No    No flame
  0.25  476  No    No flame
  0.25  478  No    No flame
  0.25  480  Yes  20  Hot flame
  0.25  490 Yes   15  Hot flame
Conclusions:
Under the study conditions, the auto-ignition temperature of the test substance was determined to be between 475 and 480°C.
Executive summary:

A study was conducted to determine the auto-ignition temperature of the test substance according to ASTM Method E-659. The method was abbreviated to determine a range for the autoignition temperature of the sample. Under the study conditions, the auto-ignition temperature of the test substance was determined to be between 475 and 480°C (Herssens, 2014).

Description of key information

The auto-ignition temperature was determined according to ASTM Method E-659 method (Herssens, 2014).

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
475 °C

Additional information