Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28.05.2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)

Test material

Constituent 1
Reference substance name:
1,4-Benzenedicarboxylic acid, 1,4-diisononyl ester
EC Number:
700-453-0
Cas Number:
59802-05-0
Molecular formula:
C26H42O4
IUPAC Name:
1,4-Benzenedicarboxylic acid, 1,4-diisononyl ester
Test material form:
liquid

Results and discussion

Results of test series for explosivesopen allclose all
Key result
Test series:
other: Test EC A. 14
Remarks:
according to the EC-Commission Regulation No 440/2008 of 30 May 2008 (SPZ-Report 073-10)
Method:
UN Test 3 (a) (ii): BAM Fallhammer
Parameter:
limiting impact energy (J)
Value:
40
Result:
result is considered "-" (negative)
Remarks:
None of the six single tests with an impact energy of 40 J showed any sparking or exploding. Therefore the series with an impact energy of 7.5 J was not necessary. No impact sensitivity of the test item was observed.
Remarks on result:
limiting impact energy > 40 J
Key result
Test series:
other: Test EC A.14
Remarks:
according to the EC-Commission Regulation No 440/2008 of 30 May 2008 (SPZ-Report 073-10)
Method:
other: Thermal sensitivity
Parameter:
other: The test has to be performed three times with an orifice diameter of 6 mm. In case of negative results (no explosion, i.e. no fragmentation or only two fragments of the steel tube), the test has to be repeated three times with an orifice diameter of 2 mm.
Value:
0
Result:
result is considered "-" (negative)
Remarks:
No thermal sensitivity of the test item induced by heating under defined confinement was observed.
Remarks on result:
other: No thermal sensitivity of the test item induced by heating under defined confinement was observed.

Any other information on results incl. tables

As the test item was neither shock sensitive nor thermally sensitive, according to the criteria of the EEC test method A.14 it does not represent an explosive hazard and should not be considered to present a danger of explosion.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions: