Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2007
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study follows an ASTM guideline but is not in accordance with GLP criteria.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D3278-96 e-1 "Flash Point of Liquids by Small Scale Closed-Cup Apparatus"
Deviations:
not specified
Principles of method if other than guideline:
Study follows Test Method A (flash/ no flash at a target temp.)
GLP compliance:
no
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
DONA
IUPAC Name:
DONA
Details on test material:
- Name of test material (as cited in study report): 144560-059-5
- Physical state: Clear, colorless liquid

Results and discussion

Flash point
Flash point:
> 93 °C
Atm. press.:
982.7 hPa

Any other information on results incl. tables

The test was performed at specific temperatures of 20 °C (68 °F), 38 °C (100 °F), 60 °C (140 °F), and 93 °C (200 °F). Additionally, the sample was progressively heated at a rate of 1.1 °C/min (2 °F/min) between these temperatures and tested every minute. No flash was detected at any tested temperature. The highest temperature tested for flash was 93 °C (200 °F).

Applicant's summary and conclusion

Conclusions:
DONA has no flash point under atmospheric conditions (982.7 hPa) up to 93 °C
Executive summary:

The flash point of DONA was tested using a closed cup flash-point apparatus. The test was performed at temperatures ranging from 20 °C (68 °F) to 93 °C (200 °F) at 982.7 hPa (737.1 mm Hg) atmospheric pressure. No flash point was observed. The highest temperature tested for flash was 93 °C (200 °F). This study was conducted in accordance with ASTM D3278-96: "Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus" but is not compliant with GLP standards. Therefore, the study is classified as reliable with restrictions.