Environmental fate & pathways

Biodegradation in water: screening tests

Currently viewing:

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09 July to 07 August 1996
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1996
Report date:
1996

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 F (Ready Biodegradability: Manometric Respirometry Test)
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
Ethyl 2-ethyl-6,6-dimethylcyclohex-2-ene-1-carboxylate
EC Number:
261-020-5
EC Name:
Ethyl 2-ethyl-6,6-dimethylcyclohex-2-ene-1-carboxylate
Cas Number:
57934-97-1
Molecular formula:
C13H22O2
IUPAC Name:
ethyl 2-ethyl-6,6-dimethylcyclohex-2-ene-1-carboxylate
Constituent 2
Chemical structure
Reference substance name:
Ethyl 2,3,6,6-tetramethylcyclohex-2-ene-1-carboxylate
EC Number:
278-776-7
EC Name:
Ethyl 2,3,6,6-tetramethylcyclohex-2-ene-1-carboxylate
Cas Number:
77851-07-1
Molecular formula:
C13H22O2
IUPAC Name:
ethyl 2,3,6,6-tetramethylcyclohex-2-ene-1-carboxylate
Specific details on test material used for the study:
Test material name (as stated in report): Givescone
Batch No. 261026
Appearance: Colourless to yellow pale liquid

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, domestic, non-adapted
Details on inoculum:
Fresh activated sludge from a biological waste water treatment plant treating predominantly domestic sewage (City of Geneva) was used. The sludge is collected in the morning , washed three times in the mineral medium (by centrifuging at 1000g for 10 minutes , discarding the supernatant and resuspending in mineral medium) and kept aerobic until being used on the same day.
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
100 mg/L
Based on:
test mat.
Parameter followed for biodegradation estimation
Parameter followed for biodegradation estimation:
O2 consumption
Reference substance
Reference substance:
aniline
Remarks:
100 mg/l

Results and discussion

% Degradation
Key result
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
28 d

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Interpretation of results:
not readily biodegradable
Conclusions:
Givescone undergoes no biodegradation after 28 days in the test conditions. Thus, Givescone should be regarded as not readily biodegradable according to this test. The curves obtained with Aniline alone and with Givescone + Aniline show no significant toxic effect of Givescone on the micro-organisms at the test concentration.
Executive summary:

The ready biodegradability of Givescone has been determined by the Manometric Respirometry test according to the OECD Guideline No. 301 F.

Givescone undergoes no biodegradation after 28 days in the test conditions. Thus, Givescone should be regarded as not readily biodegradable according to this test. At the concentration used in the test (100 mg/l), Givescone is not inhibitory to the micro organisms.