Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 March to 28 April 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
Ethyl 2-ethyl-6,6-dimethylcyclohex-2-ene-1-carboxylate
EC Number:
261-020-5
EC Name:
Ethyl 2-ethyl-6,6-dimethylcyclohex-2-ene-1-carboxylate
Cas Number:
57934-97-1
Molecular formula:
C13H22O2
IUPAC Name:
ethyl 2-ethyl-6,6-dimethylcyclohex-2-ene-1-carboxylate
Constituent 2
Chemical structure
Reference substance name:
Ethyl 2,3,6,6-tetramethylcyclohex-2-ene-1-carboxylate
EC Number:
278-776-7
EC Name:
Ethyl 2,3,6,6-tetramethylcyclohex-2-ene-1-carboxylate
Cas Number:
77851-07-1
Molecular formula:
C13H22O2
IUPAC Name:
ethyl 2,3,6,6-tetramethylcyclohex-2-ene-1-carboxylate
Specific details on test material used for the study:
Test material name (as stated in report): Givescone
Batch No. VE00409039
Appearance: colourless to pale yellow liquid
Expiration date: January 21, 2018

Results and discussion

Flash point
Key result
Flash point:
104 °C
Atm. press.:
1 013 hPa

Any other information on results incl. tables

The results of the main tests are:

First determination: Flash point corrected for atmospheric pressure: 104.0°C

Second determination: Flash point corrected for atmospheric pressure: 104.0°C

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The results of the two tests were averaged and rounded off to the nearest 0.5°C to obtain the final flash point value: 104.0 °C.
Executive summary:

The Flash point of Givescone was determined by the Pensky-Martens method according to the ISO 2719. The result is 104.0°C