Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
Phosphinic acid, P-[3-(acetyloxy)-3-cyanopropyl]-P-methyl-, butyl ester
EC Number:
605-460-1
Cas Number:
167004-78-6
Molecular formula:
C11 H20 N O4 P
IUPAC Name:
Phosphinic acid, P-[3-(acetyloxy)-3-cyanopropyl]-P-methyl-, butyl ester
Test material form:
liquid: viscous

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficientopen allclose all
Type:
Pow
Partition coefficient:
14.8
Temp.:
22 °C
pH:
6.8
Remarks on result:
other: Temperature +/- 1°C
Type:
log Pow
Partition coefficient:
1.2
Temp.:
22 °C
pH:
6.8
Remarks on result:
other: Temperature +/- 1°C

Any other information on results incl. tables

Calibration
Preparation of the Reference Solutions



The preparation of the reference solutions is described in the following table:






















































































Reference materialPurity
[%]
Amount
[mg]
Adjusted
to x [mL]
Aliquot
[mL]
Adjusted
to x [mL]
Concentration
[mg/L]
4-Acetylpyridine95.946.5050.01.2525.044.6
Acetanilide99.9951.3350.01.2525.051.3
Benzonitrile99.959.4150.00.5025.023.7
Cinnamic alcohol98.558.1450.01.2525.057.3
Atrazine97.447.63100.02.5025.046.4
Benzophenone99.948.8050.01.0025.039.0
Phenyl benzoate99.951.54100.01.5025.030.9
Thiourea (dead time)100.147.1250.01.2525.047.2

Reference Stock Solution: The reference materials were weighed into volumetric flasks which were adjusted to the mark with acetonitrile / water (40/60, v/v).


Reference Single-Solutions: An aliquote of each reference stock solution was pipetted into separate 25 mL volumetric flasks and then filled up to mark with acetonitrile / water (40/60, v/v).


Reference Mix-Solution: An aliqoute of each reference stock solution was pipetted into one 25 mL volumetric flask and then filled up to mark with acetonitrile / water (40/60, v/v).


 


Measured Results from the Calibration Solutions
The measured retention times of the used reference materials are summarized in the following table:


Measured Results from the Calibration Solutions
The measured retention times of the used reference materials are summarized in the following table:


 




































































Reference material

Retention time tR [min]


1st Injection



Retention time tR [min]


2nd Injection



Retention time tR [min]


3rd Injection



Retention time tR [min]


Mean


4-Acetylpyridine3.7693.7763.7673.771
Acetanilide5.1325.1565.1485.145
Benzonitrile10.76710.88210.87810.842
Cinnamic alcohol8.1108.1668.1598.145
Atrazine14.55414.46314.62314.604
Benzophenone36.76337.23437.25137.083
Phenyl benzoate60.09960.91160.96160.657
Thiourea (dead time)t0 = 2.486t0 = 2.489t0 = 2.480t0 = 2.485

 


Calculation of Log K’
In the following table the measured and calculated data as well as the known POW-values of the reference materials for calibrating the measurement are summarized.
The log k’-value was calculated from the mean values as follows:


k’ = tr - t0 / t0





















































Reference materialMean retention
time tR [min]
log k’Theoretical
log POW
4-Acetylpyridine3.771-0.28610.5
Acetanilide5.1450.02961.0
Benzonitrile10.8420.52671.6
Cinnamic alcohol8.1450.35751.9
Atrazine14.6040.68812.6
Benzophenone37.0831.14373.2
Phenyl benzoate60.6571.36943.6

 


Determination of the log POW of the Test Item
Preparation of the Test Item Solution
266.6 mg of the test item were weighed into a 25 mL volumetric flask and filled up to the mark with acetonitrile/water, 40/60 (v/v). With regard to the purity of the test item (90.1 %) the concentration of the resulted test solution was 9608 mg/L.

Measured Results and Determination of log K’ and log POW
To calculate the result, the equation of the calibration curve had to be transformed as follows:
Y = a * x + b >> x = (Y - b) / a
with:


a = 0.504137 a = slope of the calibration curve
b = -0.490097 b = ordinate intercept
Y = log k’ x = log POW
In the following table the measured retention time values of the test item, the calculated log k’-value and the resulting log POW values are summarized:








































 1st Inj.2nd Inj.3rd Inj.Mean value
Retention time (test substance)5.5975.6155.6125.608
log k’0.09770.10020.09980.0992
log POW1.1661.1711.1701.169
POW14.6614.8314.7914.8

 


Result:
The partition coefficient of the test item butyl (3-acetoxy-3-cyanopropyl)-methylphosphinate (AE F125869), technical substance, was at 20 °C and at neutral HPLC conditions:
POW = 14.8
log POW = 1.2
The pH value of the water used for the HPLC eluent was pH = 6.8.


 


 


 

Applicant's summary and conclusion