EC number: 445-100-9 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
Emergency measure - Inhalation: Remove person to fresh air. If not breathing, give
artificial respiration. If breathing is difficult, give
oxygen. Seek medical attention.
Emergency measure - Eyes: Flush immediately with plenty of water for at least 15
minutes. Seek medical attention.
Emergency measure - Skin: Flush immediately with plenty of water for at least 15
minutes . Remove contaminated clothing. Seek medical
attention. Wash contaminated clothing before reusing.
Emergency measure - Ingestion: Seek medical attention immediately.
Fire-fighting measures
Recommended extinguishing agent: Carbon dioxide, chemical foam and water mist.
Product arising from burning: May emit toxic fumes, including CO and CO2, hydrocarbons,
smoke, soot when burned.
Product determined by test: N
Protective equipment: Fire fighters should wear full protective clothing and self
contained breathing apparatus.
Accidental release measures
Emergency measures in case of spillage: Sweep up and place into a suitable container for disposal.
Dispose of material in accordance with goverment
requirements and ensure conformity to local disposal
regulations. To clean contaminated floors, flush with
abundant quantities of water into sewerage treatment system
if permitted by local regulations. If not permitted,
collect water and treat.
Handling and storage
Handling: The test substance will only be used in the IC industry by
trained personnel. Exposure is minimal. Skin contact is
avoided by the use of chemical resistant gloves and suitable
protective clothing. Inhalation is avoided by use of
appropriate respirators.
Mechanical room ventilation is provided, and special local
exhaust is recommended at points where vapours can be
released into the workplace air.
Storage: The substance should be stored in closed, original container
in a cool, dry area at 50 - 90°F. Do not store in direct
sunlight or expose to light. Keep container closed when not
in use. Avoid storing longer than a year.
Packaging of the substance and or preparation: The preparation is packaged into either one gallon or quart
bottles, which are put in a cardboard box.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Transport code: 1325 Flammable solid, organic, N.O.S.
Transport: The test substance should be kept in an appropriate, tightly
closed container during transport. Containers should be
stored upright and secured against falling down. Containers
should be suitably labelled and sealed.
Do not expose to any UV light source.
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Stability and reactivity
Danger other than fire: Avoid heat, sparks and static electricity. Avoid conditions
which may cause material to become airborne.
Incompatible with alkaline solutions
Chemical reaction with water: None reported.
Dust explosion: The material is only present in low concentration in the
liquid preparation.
Dust explosion determined by test: N
Disposal considerations
Industry - Possibility of recovery/recycling: Not applicable.
Industry - Possibility of neutralisation: Not applicable.
Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of the preparation
mixed with inert material (e.g. sand or soil) may be
disposed of at an authorised tip in accordance with local
regulations.
Industry - Possibility of destruction - incineration: The usual route to destruction of this material is by
dissolution into a cleaning or wash solvent followed by
incineration. Flue gases will be scrubbed.
Industry - Possibility of destruction - water purification: In the unlikely event that the preparation should enter the
water treatment systems, contaminated water should be
treated by means of flocculation precipitation. The
precipitated material should be incinerated.
Industry - Possibility of destruction - other: None known.
Public at large - Possibility of recovery/recycling: Not applicable as the substance will not be used by the
general public.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.