Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 299-434-3 | CAS number: 93882-40-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- (Q)SAR
- Adequacy of study:
- weight of evidence
- Study period:
- 15th November 2016
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- results derived from a valid (Q)SAR model, but not (completely) falling into its applicability domain, with adequate and reliable documentation / justification
- Justification for type of information:
- QSAR prediction
- Guideline:
- other: REACH guidance on QSARs R.6.
- Principles of method if other than guideline:
- KOWWIN™ Program (v1.68) (excuted by EPI Suite in QSAR Toolbox 3.4.0.17). Estimates the log octanol-water partition coefficient, log KOW, of chemicals using an atom/fragment contribution method.
- GLP compliance:
- no
- Remarks:
- Not applicable to QSAR models
- Type of method:
- other: QSAR
- Partition coefficient type:
- octanol-water
- Specific details on test material used for the study:
- The use of a QSAR model was used to clarify the partition coeffecient of the Substance and ensure that the value is reflects the major component for that Substance.
Log Kow values were estimated using KOWWIN (v1.68) computer program excuted by EPI Suite v4.10. The LogKow (KOWWIN) program estimates the log octanol/water partition coefficient (log P) of organic chemicals using an atom/fragment contribution method - Key result
- Type:
- log Pow
- Partition coefficient:
- > 10
- Temp.:
- 25 °C
- Remarks on result:
- not measured/tested
- Details on results:
- EpiWin/KOWWIN (v1.68) computer program excuted by EPI Suite v4.10 was used to estimate Log Kow. The Substance is a high molecular weight, long chain hydrocarbon which exceeds the applicability domain of KOWWIN, therefore the the value estimated for log Pow should be considered with restrictions. Therefore as the appliacability domain of the models covers log Kow up to 10, although the estimate exceeds this and based on the uncertainty, the value should be given as a log Kow >10.
- Conclusions:
- EpiWin/KOWWIN (v1.68) computer program excuted by EPI Suite v4.10 was used to estimate Log Kow. The Substance is a high molecular weight, long chain hydrocarbon which exceeds the applicability domain of KOWWIN, therefore the the value estimated for log Pow should be considered with restrictions. Therefore as the appliacability domain of the models covers log Kow up to 10, although the estimate exceeds this and based on the uncertainty, the value should be given as a log Kow >10.
- Executive summary:
The substance is considered to be a UVCB (Chemical Substances of Unknown or Variable Composition, Complex Reaction Products and Biological Materials). The complex nature and physical properties of the Substance resulted in 3 peaks in the Octanol/Water Partition Coefficient study. In this study HPLC-UV detection was used however it was noted that use of UV detection is limited to those components of UVCB materials with chromophoric functionality. The major component is considered to have no significant UV-Vis absorbing functionality. Other detectors may have provided a different set of responses, however, in the opinion of the Study Director, the experimental design and conditions presented in this study were deemed to be most appropriate for the estimation of Log POW for this test substance.
The complex nature and physical properties of the substance made it difficult to provide a suitable log Kow value. Consequently, QSAR was used to provide clarity and reflect the representative chemistry of the Substance model is a US EPA accepted QSAR method for organic chemicals properties assessment. EpiWin/KOWWIN (v1.68) computer program excuted by EPI Suite v4.10 was used to estimate Log Kow. The Substance is a high molecular weight, long chain hydrocarbon which exceeds the applicability domain of KOWWIN, therefore the the value estimated for log Pow should be considered with restrictions. Therefore as the appliacability domain of the models covers log Kow up to 10, although the estimate exceeds this and based on the uncertainty, the value should be given as a log Kow >10.
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- January 25, 2016 - March 21, 2016
- Reliability:
- 1 (reliable without restriction)
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient)
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
- GLP compliance:
- yes
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Specific details on test material used for the study:
- Batch Number: E00268-011-113/E00350-276
Sample Retest Date: March 26, 2017
Purity: 100% - Analytical method:
- high-performance liquid chromatography
- Key result
- Type:
- log Pow
- Partition coefficient:
- > 6.5
- Temp.:
- 40 °C
- pH:
- 6
- Details on results:
- The three aliquots of the 100 mg/L EXP1504385 solution were sequentially injected. The EXP1504385 test substance reproducibly eluted as three peaks on the UV detector. The capacity factor (k) for each peak was calculated based on the corresponding retention times and the results for the three injections were averaged. The corresponding estimated mean Log POW for the three test substance peaks was calculated to be <1.00, 1.06, and >6.50, respectively. The calculated mean retention times, capacity factors, and mean n octanol/water partition coefficients for EXP1504385 are presented in Table 5.
- Conclusions:
- Under the chromatographic conditions specified, the Substance eluted as three discrete peaks, corresponding to mean estimated log POW values of <1.00, 1.06 and >6.50.
- Executive summary:
The test was performedbased on procedures in the U.S. EPA Product Properties Test Guidelines, OPPTS 830.7570,Partition Coefficient (n-Octanol/Water), Estimation by Liquid Chromatography(1); OECD Guideline for Testing of Chemicals, 117,Partition Coefficient (n-octanol/water), High Performance Liquid Chromatography (HPLC) Method(2); Official Journal of the European Communities No. L383. Method A.8: Partition Coefficient(3) and TSCA Title 40 of the Federal Code of Regulations, Part 796, Section 1570: Partition Coefficient (n-Octanol/Water) – Estimation by Liquid Chromatography(4).
Under the chromatographic conditions specified, EXP1504385 eluted as three discrete peaks. The mean log POWfor each of the peaks is presented in the following table:
Peak Number
Mean Log Pow
1
<1.00
2
1.06 ± 0.0023
3
>6.50
Referenceopen allclose all
Table 5
Logn-Octanol/Water Partition Coefficients (Log POW) Based on UV Data for EXP1504385
Sample Number (523C-207,218-) |
Retention Time (minutes) |
Mean () Standard Deviation (SD)1 |
Capacity Factor (k)1,2 |
Mean () Standard Deviation (SD)1 |
Log k1 |
POW1 |
Log POW1 |
Mean () Standard Deviation (SD)1 |
12631 (Injection 1) (Peak 1) 12631 (Injection 2) (Peak 1) 12631 (Injection 3) (Peak 1) |
0.793 0.792 0.793 |
= 0.793 SD = 0.00058 |
-0.465 -0.466 -0.465 |
= -0.465 SD = 0.00039 |
N/A N/A N/A |
<10 <10 <10 |
<1.00 <1.00 <1.00 |
= <1.00 SD = N/A |
12631 (Injection 1) (Peak 2) 12631 (Injection 2) (Peak 2) 12631 (Injection 3) (Peak 2) |
1.844 1.843 1.843 |
= 1.843 SD = 0.00058 |
0.243 0.243 0.243 |
= 0.243 SD = 0.00039 |
-0.614 -0.615 -0.615 |
11.6 11.4 11.4 |
1.06 1.06 1.06 |
= 1.06 SD = 0.0023 |
12631 (Injection 1) (Peak 3) 12631 (Injection 2) (Peak 3) 12631 (Injection 3) (Peak 3) |
24.789 24.791 24.792 |
= 24.791 SD = 0.0015 |
15.7 15.7 15.7 |
= 15.7 SD = 0.0010 |
1.20 1.20 1.20 |
>3,162,278 >3,162,278 >3,162,278 |
>6.50 >6.50 >6.50 |
= >6.50 SD = N/A |
N/A = Not Applicable 1 Values obtained utilizing Microsoft®Excel 2010 in full precision mode. Manual calculations may differ slightly. 2 Capacity factor (k) is the sample retention time minus the mean column dead time (1.483 minutes for thiourea) divided by the mean column dead time. |
Description of key information
EpiWin/KOWWIN (v1.68) computer program excuted by EPI Suite v4.10 was used to estimate Log Kow. The Substance is a high molecular weight, long chain hydrocarbon which exceeds the applicability domain of KOWWIN, therefore the the value estimated for log Pow should be considered with restrictions. Therefore as the appliacability domain of the models covers log Kow up to 10, although the estimate exceeds this and based on the uncertainty, the value should be given as a log Kow >10.
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 10
- at the temperature of:
- 25 °C
Additional information
Initial attempts were made to experimentally determine the Partition Coefficient (Kow) for registration of the Substance. The Substance is considered to be a UVCB (Chemical Substances of Unknown or Variable Composition, Complex Reaction Products and Biological Materials). The complex nature and physical properties of the Substance resulted in 3 peaks in the Octanol/Water Partition Coefficient study. In this study HPLC-UV detection was used however it was noted that use of UV detection is limited to those components of UVCB materials with chromophoric functionality. The major component is considered to have no significant UV-Vis absorbing functionality. Other detectors may have provided a different set of responses, however, in the opinion of the Study Director, the experimental design and conditions presented in this study were deemed to be most appropriate for the estimation of Log Kow for this test substance.
The complex nature and physical properties of the substance made it difficult to provide a suitable log Kow value. Consequently, a QSAR model was used to provide clarity and reflect the major component of the Substance. This was executed using KOWWIN (EpiSuite) in the QSAR Toolbox 3.4.0.17.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.