Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
January 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Remarks:
This study was considered as reliable with restrictions because it was not conducted under GLP and there are some lack of details in the study report.
Reason / purpose for cross-reference:
reference to other study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
other: Norm DIN 51794
Deviations:
not specified
GLP compliance:
no
Key result
Auto-ignition temperature:
250 °C
Atm. press.:
994 hPa
Remarks on result:
other: Time lag: 4 minutes

Preliminary study:

Time lag: 4 minutes ; amount 5 drops = 3 mL

Temperature   Results
 240°C  No-ignition
 260°C  Ignition

The preliminary results indicate that the auto-ignition temperature is aroud 260°C at 994 hPa.

Main study:

Time lag: 4 minutes ; amount of test item: 1 to 5 droplets = 0.6 to 3 mL

 Temperature exp 1  exp 2 exp 3 exp 4 exp 5
 240°C  No ignition No ignition   No ignition  No ignition  No ignition
 250°C No ignition  No ignition No ignition Ignition  -
 260°C Ignition   -  -  -

During the main test the auto-ignition temperature of nerol was determined to be 250°C at 994 hPa.

Conclusions:
The auto ignition temperature of nerol was determined to be 250 °C at 994 hPa.
Executive summary:

The determination of the auto flammability was performed in accordance with regulation (EC) No 440/2008 method A.15 "Auto-Ignition Temperature (Liquids and Gases)" (May 2008) and the Standard Test Method DIN 51794.

In the preliminary test, ignition was observed at around 260 °C at 994 hPa.

In the main test, the auto ignition temperature of nerol was determined to be 250 °C at 994 hPa.

 

Description of key information

The auto ignition temperature of nerol is 250 °C at 994 hPa.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
250 °C

Additional information

Key study conducted according to EU A.15 guideline and DIN 51794 method. The result is scientifically acceptable but not obtained under GLP. Therefore a reliability of 2 (reliable with restrictions) was assigned.