Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 946-248-1 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- December 07, 2012
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 012
- Report date:
- 2013
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying Ocular Corrosives and Severe Irritants)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU method B.47 (Bovine corneal opacity and permeability test method for identifying ocular corrosives and severe irritants)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- Citronellyl 3-methylcrotonate
- EC Number:
- 244-019-4
- EC Name:
- Citronellyl 3-methylcrotonate
- Cas Number:
- 20770-40-5
- Molecular formula:
- C15H26O2
- IUPAC Name:
- 3,7-dimethyloct-6-en-1-yl 3-methylbut-2-enoate
- Reference substance name:
- 3,7-dimethyloctyl 3-methyl-2-butenoate
- EC Number:
- 275-360-7
- EC Name:
- 3,7-dimethyloctyl 3-methyl-2-butenoate
- Cas Number:
- 71383-07-8
- Molecular formula:
- C15H28O2
- IUPAC Name:
- 3,7-dimethyloctyl 3-methylbut-2-enoate
- Reference substance name:
- 3,7-dimethyloct-7-en-1-yl 3-methylbut-2-enoate
- Cas Number:
- 74499-48-2
- Molecular formula:
- C15H26O2
- IUPAC Name:
- 3,7-dimethyloct-7-en-1-yl 3-methylbut-2-enoate
- Test material form:
- liquid
Constituent 1
Constituent 2
Constituent 3
- Specific details on test material used for the study:
- Identity: SINODOR CQ U/A - 6099932
Batch-No.: VE00172025
Purity: > 97% (sum isomers)
Stability in Solvent: Not relevant
Storage: At room temperature, protected from light and moisture
Expiration Date: May 2013
Test animals / tissue source
- Species:
- other: Bovine eyes
- Strain:
- other: Corneas
- Details on test animals or tissues and environmental conditions:
- Freshly isolated bovine eyes from at least 9 month old donor cattle were collected from the
abattoir. Excess tissue was removed from the excised eyes. The isolated eyes were
transported to the laboratory in Hank’s BSS supplemented with streptomycin / penicillin at
ambient temperature. The corneae were isolated on the same day after delivery of the eyes
and used directly for the BCOP test.
All eyes were carefully examined macroscopically for defects. Those presenting defects such
as vascularization, pigmentation, opacity and scratches were discarded. The cornea was
carefully removed from the eye using scalpel and rounded scissors. A rim of about 2 mm of
tissue (sclera) was left for stability and handling of the isolated cornea. All corneae used in
the experiment were collected in Hank’s BSS supplemented with streptomycin / penicillin and
checked finally with a view box for defects listed above.
Each isolated cornea was mounted in a specially designed cornea holder according to the
description given in OECD guideline 437, annex III, that consists of anterior and posterior
compartments, which interface with the epithelial and endothelial sides of the cornea,
respectively. The endothelial side of the cornea was positioned against the sealing ring (Oring)
of the posterior part of the holder. The cornea was gently flattened over the O-ring but
stretching was avoided. After the anterior part of the holder was positioned on top of the
cornea and fixed in place with screws, both compartments of the holder were filled with
complete medium. The posterior compartment was filled first to return the cornea to its
natural convex position. Care was taken to assure no air bubbles were present within the
compartments.
For equilibration, the corneae in the holder were incubated in a vertical position for one hour
at 32 ± 1 °C in a water-bath.
At the end of the incubation period, the basal opacity was determined (t0).
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- yes
- Amount / concentration applied:
- The anterior compartment received the test item or negative or positive control at a volume
of 0.75 mL on the surface of the corneae.
The test item was tested undiluted. The positive control 2-Ethoxyethanol was tested neat.
Saline was used as negative control item. - Duration of treatment / exposure:
- 10 minutes
120 minutes - Number of animals or in vitro replicates:
- Negative control: 3 Corneae
Positive control: 3 Corneae
Test item: 3 Corneae - Details on study design:
- The experiment was performed to determine an irritation effect of the test item on the
corneal opacity.
The anterior compartment received the test item or negative or positive control at a volume
of 0.75 mL on the surface of the corneae and was incubated at 32 ± 1 °C in the water-bath,
while the corneae were in a horizontal position.
The test item was tested undiluted. The positive control 2-Ethoxyethanol was tested neat.
Saline was used as negative control item.
The incubation time lasted ten minutes.
After the test item or control items, respectively, were rinsed off from the application side
with saline, fresh cMEM was added into the anterior compartment. The corneae were then
incubated at 32 ± 1 °C for further two hours in a vertical position, followed by a 2nd opacity
reading (t130).
In the second step of the assay, permeability of the cornea was determined. 1 mL of a Nafluorescein
solution, 0.5 % (w/v) dissolved in HBSS (Hank’s buffered salt solution), was
placed in the anterior compartment. Corneae were incubated again in a horizontal position
for an additional 90 minutes at 32 ± 1 °C in the water-bath. The optical density of an aliquot
of the mixed complete medium from the posterior chamber was measured
spectrophotometrically at 490 nm (OD490).
Opacity Measurement
The opacitometer determines changes in the light transmission passing through the corneae,
and displays a numerical opacity value. This value was recorded in a table. The
opacitometer was calibrated as described in the manual and the opacity of each of the
corneae was determined by reading each holder placed in the photoreceptor compartment
for treated cornea.
The basal opacity of all corneae was recorded. Each corneae with a value of the basal
opacity > 7 was discarded. Sets of three corneae were used for treatment with the test items
and the negative and positive controls.
Complete medium was completely removed from the anterior compartment and replaced by
the test item, positive or negative control. The anterior compartment was plugged. The
cornea was turned to a horizontal position and slightly rotated to ensure uniform covering of
the cornea with the test item and was incubated in a water-bath at 32 ± 1 °C for ten minutes
followed by two hours incubation after replacing the test item solution by cMEM in a vertical
position. Afterwards, the opacity value was determined again.
Permeability Determination
Following the opacity readings, the permeability endpoint was measured as an indication of
the integrity of the epithelial cell sheets. After the final opacity measurement was performed,
the complete medium was removed from the anterior compartment and replaced by 1 mL of
a 0.5% (w/v) sodium fluorescein solution in HBSS. Corneae were incubated again in a
horizontal position for 90 minutes in a water-bath at 32 ± 1 °C. Complete medium from the
posterior compartment was removed, well mixed and the optical density at 490 nm (OD490)
was determined with a spectrophotometer.
Criteria for Determination of a Valid Test
The test was acceptable if the in vitro irritation score of the positive control was ≥ 30 and the
in vitro irritation score of the negative control was ≤ 3.
Results and discussion
In vitro
Results
- Irritation parameter:
- in vitro irritation score
- Value:
- 3.01
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Other effects / acceptance of results:
- Corneal Opacity :
The opacity reading for the test article was 2.67, 1.67 and 4.67.
The mean opacity reading for the negative control was 1.33.
The opacity reading for the positive control was 78.67, 74.67 and 81.67.
Corneal Permeability:
The optical density for the test article was 0.004, 0.001 and -0.003.
The mean optical density for the negative control was 0.048.
The optical density for the positive control was 0.486, 0.209 and 0.318.
Applicant's summary and conclusion
- Interpretation of results:
- not classified
- Conclusions:
- With the negative control (saline) neither an increase of opacity nor permeability of the
corneae could be observed (mean in vitro irritation score 2.05).
The positive control (2-Ethoxyethanol) showed clear opacity and distinctive permeability of
the corneae (mean in vitro irritation score 83.40) corresponding to a classification as
corrosive / severe irritant to the eye (CLP/EPA/GHS (Cat 1)).
Relative to the negative control, the test item SINODOR CQ U/A - 6099932 caused a very
slight increase of the corneal opacity, whereas a rise of the permeability values was not
observed. The calculated mean in vitro irritation score was 3.01 (threshold for corrosivity /
severe irritancy: ≥ 55.1). According to OECD 437 the test item is classified as not corrosive /
not severe irritant to the eye. - Executive summary:
This in vitro study was performed to assess the corneal irritation and damage potential of
SINODOR CQ U/A - 6099932 by means of the BCOP assay using fresh bovine corneae.
After a first opacity measurement of the fresh bovine corneae (t0), the neat test item
SINODOR CQ U/A - 6099932, the positive, and the negative controls were applied to
corneae and incubated for 10 minutes at 32 ± 1 °C. The posterior chamber contained MEM
medium supplemented with sodium bicarbonate and L-glutamine and 1% fetal calf serum
(FCS) (complete medium = cMEM). After the incubation phase the test item, the positive,
and the negative controls were each rinsed from the corneae. Further, the corneae were
incubated for another 120 minutes at 32 ± 1 °C in complete medium, and opacity was
measured a second time (t130).
After the opacity measurements permeability of the corneae was determined by measuring
spectrophotometrically the transfer of sodium fluorescein after incubation in a horizontal
position for 90 minutes at 32 ± 1 °C.
With the negative control (0.9% (w/v) NaCl solution in deionised water) neither an increase
of opacity nor permeability of the corneae could be observed.
The positive control (2-Ethoxyethanol) showed clear opacity and distinctive permeability of
the corneae corresponding to a classification as corrosive / severe irritant to the eye
(CLP/EPA/GHS (Cat 1)).
Relative to the negative control, the test item SINODOR CQ U/A - 6099932 caused a very
slight increase of the corneal opacity. Permeability effects were not observed. The calculated
mean in vitro irritation score was 3.01. According to OECD 437 the test item is classified as
not corrosive / not severe irritant to the eye.
In conclusion, according to the current study and under the experimental conditions
reported, the test item SINODOR CQ U/A - 6099932 is not corrosive / not severe irritant to
the eye (CLP/EPA/GHS (Cat 1)).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.