Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27 February 2020 to 13 March 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D7094 (Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester)
Version / remarks:
2012
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester
Specific details on test material used for the study:
- Purity/Composition correction factor: No correction factor required
Key result
Flash point:
101 °C
Remarks on result:
other: standard pressure (1013.25 hPa) assumed

Preliminary Test

The estimated flash-point of the test material was 103.0 °C.

Main Study

The flash-point of the test material was determined to be 102 and 101 °C in Test 1 and Test 2, respectively. The difference between the results obtained in Test 1 and Test 2 was ≤ 2 °C. From this, it was concluded that the flash-point of the test material is the lowest flash-point obtained.

Interpretation of results:
other: not classified according to EU criteria
Conclusions:
Under the conditions of the study the flash-point of the test material was determined to be 101 °C.
Executive summary:

The flash-point of the test material was investigated in a study which was conducted in accordance with the standardised guideline ASTM D7094, under GLP conditions, using a closed cup method (Eraflash flash-point tester).

Under the conditions of the study the flash-point of the test material was determined to be 101 °C.

Description of key information

Under the conditions of the study the flash-point of the test material was determined to be 101 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
101 °C

Additional information

The flash-point of the test material was investigated in a study which was conducted in accordance with the standardised guideline ASTM D7094, under GLP conditions, using a closed cup method (Eraflash flash-point tester). The study was awarded a reliability score of 1 in accordance with the criteria set forth by Klimisch et al. (1997).

Under the conditions of the study the flash-point of the test material was determined to be 101 °C.