Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 812-241-6 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flash point
Administrative data
- Endpoint:
- flash point of flammable liquids
- Data waiving:
- study technically not feasible
- Justification for data waiving:
- the study does not need to be conducted because the flash point is only relevant to liquids and low melting point solids
- the study does not need to be conducted because decomposition occurred during the melting point study
- other:
- Justification for type of information:
- JUSTIFICATION FOR DATA WAIVING:
The substance can be marketed in aqueous solution. However, in accordance with section 1 of REACh Annex XI, flash point is deemed unnecessary based on the weight of evidence of the composition of this form (nature of the not flammable solid substance) and its high water content. Then the aqueous solution of the substance is very unlikely to exhibit a flash point and lead to a classification according to Reg.(EC) 1272/2008.
Cross-referenceopen allclose all
- Reason / purpose for cross-reference:
- data waiving: supporting information
Reference
- Flammability:
- non flammable
For substance in its solid form : No ignition in contact with flame. No propagation in contact with a flame: not a flammable solid (CLP/GHS)
For substance marketed in a liquid form (aqueous solution) : No Flash point is anticipated due to the nature of the substance (not flammable solid) and its high water content.
A reliable experimental study was conducted on the solid test item andaccording to standard method (UN N1Test and EU method A10) under GLP.
The test item to propagate combustion in the preliminary test (identical in EC A10 and UN N1 tests), shows that the substance is non flammable.
According to Regulation (EC) No.1272/2008 (CLP) and UN Globally Harmonised System (GHS) criteria,the substance as solid failed to propagate combustion in the preliminary test (identical in EC A10 and UN N1 tests), therefore the substance is NOT classified as a flammable solid.
The substance can be marketed in aqueous solution (see '1.2-Composition') but in this marketed form, it is very unlikely to exhibit a flash point due to the nature of the substance (not flammable solid) and its high water content. Therefore, the flash point was waived and the substance is not classified as a flammable liquid.
Based on the chemical structure of the constituents of the substance and experience in handling and use of the substance, no flammable properties are anticipated if contact with air or water, therefore studies were deemed unnecessary.
Finally , the substance is not considered as classified in these hazard classes.
- Reason / purpose for cross-reference:
- data waiving: supporting information
Reference
No melting point was recorded
A fully reliable experimental study, conducted according to a recognized EU/OECD method and under GLP, is available.
No melting point was recorded but the degradation of the substance was observed between 90°C (363.2 K) and 170.5°C (443.7 K) before melting.
Data source
Materials and methods
Results and discussion
Applicant's summary and conclusion
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.