Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

General information: Remove contaminated clothes immediately and safely

After inhalation: Seek medical assistance if spray inhalation  occurs

After contact with skin: In case of contact with skin wash off immediately with soap and water

After contact with eyes: In case of contact with eyes rinse thoroughly with plenty of water and seek medical advice

After ingestion: When swallowed seek medical aid immediately and show the physician the safty data sheet

Information for physician: Treat symptomatically

Fire-fighting measures

Suitable extinguishing media: water spray jet, foam, carbon dioxide, alcohol consistent  foam

In case of fires, hazardous combustion gases are formed: carbon monoxide (CO), carbon dioxide (CO2)

Special protective equipment for firefighting: In case of fire, wear respiratory protection

Further information: Fire residues and contaminated firefighting water must be disposed in accordance with the local regulations.

Accidental release measures

personal precautionary measure: Wear suitable personal protective equipment.

environmental protection measure: Do not allow entry to drains, water courses or soil

procedure for purification/absorption: absorption with binding agent for liquids (e.g. sand, kieselguhr, absorbent for acids, universal absorbent, saw dust); thoroughly cleaning of contaminated items and floor in accordance with the local regulations. Contaminated residues and contaminated material must be disposed in accordance with the local regulations.

Handling and storage

Handling:

General information on safe use: Provide good ventilation of working area (use local exhaust ventilation during every kind of filling)

General information on industrial fire and explosion protection: Take precautionary measures against static discharges. Use electrical grounding during every kind of filling. Observe the general rules of industrial fire protection.

Storage:

Keep only in the original container

Keep container tightly closed and dry.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
3082
Shipping information
Proper shipping name and description:
Environmentally hazardous substance, liquid, n.o.s.
Chemical name:
4-methyl-6-(2,4,4-trimethylphenyl)-2H-Pyran-2-one
Language:
English
Labels:
9
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
3082
Shipping information
Proper shipping name and description:
Environmentally hazardous substance, liquid, n.o.s.
Chemical name:
4-methyl-6-(2,4,4-trimethylphenyl)-2H-Pyran-2-one
Labels:
9
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
3082
Shipping information
Proper shipping name and description:
Environmentally hazardous substance, liquid, n.o.s.
Chemical name:
4-methyl-6-(2,4,4-trimethylphenyl)-2H-Pyran-2-one
Labels:
9
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

During its lifecycle the substance is handled under strictly controlled conditions and is rigorously contained in accordance with Art. 17 and/or Art. 18.

Based on the knowledge of the basic hazards to humans and environment technical, organizational and PPE measures are taken to minimize release and exposure of this substance. National regulatory requirements for the handling of chemicals are also fulfilled. Employees are regularly trained. The efficiency of these measures is controlled e.g. by workplace measurements. In case of deviations these measures are adapted.

Exposure limit values are not available.

DNEL/DMEL values are not available.

PNEC values are not available.

Stability and reactivity

Disposal considerations

Product: Special waste incineration plant, after consultation with operators and in accordance with the local regulations

Uncleaned packaging : Packaging that cannot be cleaned should be disposed of as product waste