Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 212-141-7 | CAS number: 765-14-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Remove contaminated clothing.
If inhaled:
If difficulties occur after vapour/aerosol has been inhaled, remove to fresh air and seek medical attention.
On skin contact:
Wash thoroughly with soap and water. If irritation develops, seek medical attention.
On contact with eyes:
Wash affected eyes for at least 15 minutes under running water with eyelids held open. If irritation develops, seek medical attention.
On ingestion:
Rinse mouth immediately and then drink plenty of water, seek medical attention.
Fire-fighting measures
water spray, dry powder, foam, carbon dioxide
Advice for fire-fighters
Special protective equipment: Wear a self-contained breathing apparatus.
Further information: Collect contaminated extinguishing water separately, do not allow to reach sewage or effluent systems.
Accidental release measures
Avoid inhalation. Handle in accordance with good industrial hygiene and safety practice.
Environmental precautions
Do not empty into drains.
Methods and material for containment and cleaning up
- For large amounts: Pump off product.
- For residues: Pick up with suitable absorbent material (e.g. sand, sawdust, general-purpose binder, kieselguhr). Dispose of absorbed material in accordance with regulations.
Handling and storage
Ensure thorough ventilation of stores and work areas. Handle in accordance with good industrial hygiene and safety practice.
Remove contaminated clothing and protective equipment before entering eating areas.
Hands and/or face should be washed before breaks and at the end of the shift. When using do not eat, drink or smoke.
Protection against fire and explosion:
Prevent electrostatic charge - sources of ignition should be kept well clear - fire extinguishers should be kept handy.
Conditions for safe storage, including any incompatibilities
- Segregate from acids and acid forming substances.
- Further information on storage conditions: Containers should be stored tightly sealed in a dry place.
- Protect from direct sunlight, and from temperatures above 25 °C
- To protect product quality, maintain indicated limit temperature.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Respiratory protection: Wear respiratory protection if ventilation is inadequate.
Hand protection: Chemical resistant protective gloves (EN 374).
- Suitable materials for short-term contact (recommended: At least protective index 2, corresponding > 30 minutes of permeation time according to EN 374), e.g. nitrile rubber (0.4 mm), chloroprene rubber (0.5 mm), polyvinylchloride (0.7 mm) and other materials.
- Manufacturer's directions for use should be observed because of great diversity of types.
Supplementary note: The specifications are based on tests, literature data and information of glove manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g. temperature) it must be considered, that the practical usage of a chemical-protective glove in practice may be much shorter than the permeation time determined through testing.
Eye protection: Safety glasses with side-shields (frame goggles) (e.g. EN 166).
General safety and hygiene measures
Handle in accordance with good industrial hygiene and safety practice. Wearing of closed work clothing is required additionally to the stated personal protection equipment.
Gloves must be inspected regularly and prior to each use. Replace if necessary (e.g. pinhole leaks). Take off immediately all contaminated clothing.
Wash contaminated clothing before reuse. Hands and/or face should be washed before breaks and at the end of the shift.
Stability and reactivity
No hazardous reactions if stored and handled as prescribed/indicated.
Corrosion to metals with the exception of stainless steel.
Chemical stability
The product is stable if stored and handled as prescribed/indicated. The product can polymerize if the shelf life or storage temperature are greatly exceeded.
Possibility of hazardous reactions
Polymerization occurs with acids. Polymerization coupled with heat formation. May form unstable peroxides.
The product can polymerize if the shelf life or storage temperature are greatly exceeded.
Conditions to avoid
Avoid direct sunlight. Avoid heat.
Incompatible materials
Avoid contact to substances with an acid reaction, air.
Hazardous decomposition products
No hazardous decomposition products if stored and handled as prescribed/indicated.
Disposal considerations
- Incinerate in suitable incineration plant, observing local authority regulations.
- Contaminated packaging should be emptied as far as possible; then it can be passed on for recycling after being thoroughly cleaned.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.