Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 May 2011 - 11 July 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report Date:
2011

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
other: Differential Scanning Calorimetry (DSM)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Melting / freezing pt.:
80.3 - 129 °C

Any other information on results incl. tables

Thermographic Data – Determination 1

Thermal Event

Interpretation

Temperature

°C

K

 

Endotherm

Start of melting range

Peak melting temperature

End of melting range

80.72

122.93

126.81

354

396

400

 

Thermographic Data – Determination 2

Thermal Event

Interpretation

Temperature

°C

K

 

Endotherm

Start of melting range

Peak melting temperature

End of melting range

80.31

123.15

128.67

353

396

402

 

 

Applicant's summary and conclusion

Conclusions:
The melting temperature of the test item has been determined to be over the range 80.3 to 129°C (353 to 402 K).
Executive summary:

The melting temperature of the test item has been determined to be over the range 80.3 to 129°C (353 to 402 K) in accordance with Method Al Melting/Freezing Temperature of Commission Regulation (EC) No 440/2008 of 30 May 2008.