Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June-August 2000
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to EU guidelines and GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2000
Report Date:
2000

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Any other information on results incl. tables

Extremely flammable (Meth A9/A2): N
Highly flammable: N
Pyrophoric substance (A13): N
Highly flammable solid (A10): N
Highly flammable liquid (A9): N
Highly flammable gas (A11): N
In contact with water substance liberates highly flammable gases (A12): N
Flammable (A9): N

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
CCP-V-1 was shown to be not flammable.
Executive summary: