EC number: 249-385-9 | CAS number: 29043-70-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
General information:
In case of accident or if you feel unwell seek medical advice (show label or SDS where possible).
After contact with the eyes:
Rinse immediately with plenty of water. Seek medical advice in case of continuous irritation.
After contact with the skin:
Wash with plenty of water or water and soap. In the event of a visible skin change or other complaints, seek medical advice (show
label or SDS where possible).
After inhalation:
Provide fresh air.
After swallowing:
Give several small portions of water to drink. Do not induce vomiting.
Most important symptoms and effects, both acute and delayed
Any relevant information can be found in other parts of this section.
Indication of any immediate medical attention and special treatment needed
Further toxicology information must be observed.
Fire-fighting measures
Suitable extinguishing media:
water spray , extinguishing powder , sand , foam , carbon dioxide .
Extinguishing media which must not be used for safety reasons:
According to our present state of knowledge: none known .
Special hazards arising from the substance or mixture
not applicable
Advice for firefighters
Special protective equipment for fire fighting:
Use respiratory protection independent of recirculated air.
Accidental release measures
No special measures required.
Environmental precautions
Prevent material from entering sewers or surface waters.
Methods and material for containment and cleaning up
Take up mechanically and dispose of according to local/state/federal regulations.
Further information:
None required.
Reference to other sections
Relevant information in other sections has to be considered. This applies in particular for information given on personal protective
equipment and on disposal.
Handling and storage
General information:
No special protective measures required.
Precautions for safe handling:
No special protective measures required.
Precautions against fire and explosion:
No special precautions against fire and explosion required.
Conditions for safe storage, including any incompatibilities
Conditions for storage rooms and vessels:
none known
Advice for storage of incompatible materials:
not applicable
Further information for storage:
Keep container tightly closed.
Specific end use(s)
No data available.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Additional transport information
Additional information
- Special provisions / remarks / other:
- Not regulated for transport
Exposure controls / personal protection
Maximum airborne concentrations at the workplace:
not applicable
Exposure controls
Exposure in the work place limited and controlled
General protection and hygiene measures:
Do not eat or drink when handling.
Personal protection equipment:
Respiratory protection
not required .
Eye protection
not required .
Hand protection
not required .
Stability and reactivity
If stored and handled in accordance with standard industrial practices no hazardous reactions are known.
Relevant information can possibly be found in other parts of this section.
Conditions to avoid
none known
Incompatible materials
none known
Hazardous decomposition products
If stored and handled properly: none known . Measurements have shown the formation of small amounts of formaldehyde at
temperatures above about 150 °C (302 °F) through oxidation.
Disposal considerations
Material
Recommendation:
Dispose of according to regulations by incineration in a special waste incinerator. Small quantities may be disposed of by
incineration in an approved facility. Observe local/state/federal regulations.
Uncleaned packaging
Recommendation:
Completely discharge containers (no tear drops, no powder rest, scraped carefully). Containers may be recycled or re-used.
Observe local/state/federal regulations.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.