Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Balance Analytical balance, Sartorius BP221 (accuracy 4 decimal places)
Sieve kit CISA type manual series
Description of method: 100 g uric acid was sieved manually through the standard sieve series, and then the fractions was weighed.

GLP compliance:
no
Type of method:
sieving
Type of distribution:
mass based distribution

Test material

1
Chemical structure
Reference substance name:
Uric acid
EC Number:
200-720-7
EC Name:
Uric acid
Cas Number:
69-93-2
Molecular formula:
C5H4N4O3
IUPAC Name:
7,9-dihydro-1H-purine-2,6,8(3H)-trione
Test material form:
solid: particulate/powder
Details on test material:
It was manufactured by MOLAR CHEMICALS Ltd.

Results and discussion

Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
> 125 µm
Distribution:
ca. 0 %
No.:
#2
Size:
>= 100 - <= 125 µm
Distribution:
ca. 99.72 %
No.:
#3
Size:
> 63 - < 100 µm
Distribution:
ca. 0.28 %

Any other information on results incl. tables

> 125 micrometer = 0 %

100-125 micrometer = 99,72 %

63-100 micrometer = 0,28 %

Applicant's summary and conclusion

Conclusions:
> 125 micrometer = 0 %
100-125 micrometer = 99,72 %
63-100 micrometer = 0,28 %
Executive summary:

> 125 micrometer = 0 %

100-125 micrometer = 99,72 %

63-100 micrometer = 0,28 %