Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10.12.1993-27.01.1994
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
other: 1)Method with the falling hammer 2)Procedure with the friction apparatus 39Steel sleeve method. Nozzle diameter: 2.0 mm; Weighing: 18.4 g
Version / remarks:
Prüfung auf thermische sensibilität nach dem stahlhülsenverfahren gemass sprenstoffgesetz (StAA-Nr 4/15.01)
Prüfung auf Schlagenempfindlichkeit gemass Sprenstoffgesetz (StAA-Nr 4/15.03)
Prüfung auf Reibempfindlichkeit gemass Sprenstoffgesetz (StAA-Nr 4/15.05)
Deviations:
not specified
GLP compliance:
yes
Specific details on test material used for the study:
97% toluene-4-sulphonohydrazed; 3% Hydrated castor oil
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N
Key result
Parameter:
thermal sensitivity - Koenen test: limiting diameter (mm)
Remarks on result:
negative (not further specified)
Remarks:
t1=6s; t2=25s: no explosion t1=8s; t2=24s: no explosion t1=7s; t2=22s: no explosion
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Remarks:
1 test: decomposes in traces with odor development; 5 tests: no reaction. Overall: no reaction
Interpretation of results:
GHS criteria not met
Conclusions:
The substance is not explosive.
Executive summary:

With a diameter of the hole of 2.0 mm in the nozzle plate, no explosions were found in all three experiments. In all three experiments, the pods remained unchanged

In all 6 experiments no explosions were observed at a strike energy of 40J. In one experiment, traces of traces of decomposition with odor development were found in places.

At a friction pin load of 360N, no reaction was observed in any of the 6 experiments.

The substance is not explosive.

Description of key information

The study does not need to be conducted since the Calculated Oxygen Balance is < 200.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Calculated Oxygen Balance=146 = 1600/186.23*(2*7+10/2-2).

Justification for classification or non-classification

The substance does not need to be classified as explosive, because TSH is classified as a self-reactive substance Type D.