Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2003-12-18 to 2004-03-09
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Version / remarks:
92/69
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Lot/batch No.of test material: 0306-8715A
- Expiration date of the lot/batch: 2006-07
Key result
Remarks on result:
no self ignition observed under the test conditions
Conclusions:
Using a linear increase in temperature of about 0.5°C/min, the test item showed no exothermic reaction. The test item is considered to be not auto-flammable.
Executive summary:

A study according to EU method A.16 (EC 92/69) was conducted to determine the relative self-ignition temperature of the test item. The tests were started from ambient oven temperature. The temperature of the oven and sample were continuously recorded with a thermosensor while the temperature of the oven was increased at a rate of approximately 0.5 °C/min, the temperature of the sample was increased by about 0.5 °C/min up to 400 °C. In the course of this study the test item did not self-ignite up to this temperature. Thus, no self-ignition temperature could be stated.

Description of key information

Not auto-flammable.

Key value for chemical safety assessment

Additional information

A study according to EU method A.16 (EC 92/69) was conducted to determine the relative self-ignition temperature of the test item. The tests were started from ambient oven temperature. The temperature of the oven and sample were continuously recorded with a thermosensor while the temperature of the oven was increased at a rate of approximately 0.5 °C/min, the temperature of the sample was increased by about 0.5 °C/min up to 400 °C. In the course of this study the test item did not self-ignite up to this temperature. Thus, no self-ignition temperature could be stated.