Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
GLP compliance:
yes (incl. QA statement)
Analytical monitoring:
no
Vehicle:
no
Details on test solutions:
PREPARATION OF TEST SUBSTANCE
- The test substance was added in the required amounts according to the test concentrations directly to the test vessels with about 234 mL demineralized water.
Test organisms (species):
activated sludge, domestic
Details on inoculum:
- Inoculum: activated sludge from the municipal wastewater treatment plant of Mannheim, Germany, was collected from the aeration tank of the plant.
- Preparation of inoculum: activated sludge suspension was sieved with fine woven mesh (mesh size about 1 mm). This suspension was pre-aerated over night at room temperature. On the next day the sludge suspension was washed once with tap water and the suspension was adjusted to 3 g/L dry matter. An aliquot of this suspension was added to the test vessels to obtain a sludge concentration of 1.5 g/L dry substance.
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
180 min
Test temperature:
20.3 – 20.6 °C
pH:
7.0 - 8.0
Nominal and measured concentrations:
- Concentrations tested (nominal): 1000, 500, 250, 125 and 62.5 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessels: glass beakers (nominal volume 1 L)
- Test volume: 500 ml
- No. of replicates/control: 4
- No. of replicates/concentration: 2
- No. of replicates/reference: 2
- Synthetic medium: 16 ml/test vessel of 100-fold concentrated OECD medium
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol
Duration:
180 min
Dose descriptor:
EC10
Effect conc.:
110 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
180 min
Dose descriptor:
EC50
Effect conc.:
750 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
180 min
Dose descriptor:
other: EC80
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Details on results:
- The mean oxygen uptake of the blank controls was 16 mg/g*h
Results with reference substance (positive control):
EC50 = 8.3 mg/L

Description of key information

The inhibition of the degradation activity of activated sludge is not anticipated when introduced in appropriate low concentrations.

Key value for chemical safety assessment

Additional information

The acute toxicity of the test substance to microorganisms has been examined in a GLP guideline study according to OECD 209 with activated domestic sludge from a municipal wastewater plant [BASF SE 2012]. At test termination after 180 min, an EC10 of 110 mg/L (nominal) was determined.