Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP and Guidelinestudy

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method

Test material

Constituent 1
Test material form:
solid: crystalline

Results and discussion

Density
Type:
relative density
Density:
1.182
Temp.:
20 °C

Any other information on results incl. tables

The relative density of the test item was determined according to European Commission Council Regulation (EC) No 440/2008, Annex, Part A, A.3., OECD Guideline 109 and US EPA Product Properties Test Guideline OCSPP 830.7300. Calibrated pycnometers were initially weighed, approximately 8 to 10 g of the test item were added and the pycnometers were weighted again. Then the pycnometers were carefully filled with the displacement liquid (water) and the final weight was determined. The determination of the relative density was performed twice.

The relative density was calculated from the difference in mass of the empty and the filled pycnometer and its known volume by subtracting the known volume of the displacement liquid.

The relative density of Oxophos 64i at 20°C

as mean value of two determinations was:

D204 = 1.182

Applicant's summary and conclusion