Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Principles of method if other than guideline:
None
GLP compliance:
yes
Specific details on test material used for the study:
None
Key result
Test procedure:
other: Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state
Remarks on result:
other: not highly flammable

None

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
FAT 40865/A TE is not highly flammable / nonflammable.
Executive summary:

The flammability of FAT 40865/A TE was determined by following test guideline OPPTS 830.6315. Since, no combustion was observed in the test item train in the preliminary screening test, it is concluded that, the test item is not highly flammable / nonflammable.

Description of key information

FAT 40865/A TE was not highly flammable / nonflammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The flammability of FAT 40865/A TE was determined by following test guideline OPPTS 830.6315. Since, no combustion was observed in the test item train in the preliminary screening test, it is concluded that, the test item is not highly flammable / nonflammable.

Justification for classification or non-classification

Since, no combustion was observed in the preliminary screening test, it was concluded that, the test item is not highly flammable / non flammable and does not require classification as per the CLP (Regulation 1272/2008) criteria.