Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30 April 2001 to 03 May 2001
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP Study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report Date:
2001

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Any other information on results incl. tables

The test material has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.