Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Comparable to guideline study with acceptable restrictions
Principles of method if other than guideline:
other: Pensky-Martens
GLP compliance:
no
Type of method:
closed cup
Flash point:
138 °C
Atm. press.:
other: no data
Remarks on result:
other: no available data about the pressure
Conclusions:
Flash point was determined according to Closed-cup method (Pensky Martens) and resulted in a value of 138°C.
Executive summary:

Flash point was determined according to Closed-cup method (Pensky Martens) and resulted in a value of 138°C.

Description of key information

Flash point: 138°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
138 °C

Additional information

BASF AG (1972) determined the flash point according to closed - cup method (Pensky Martens)