Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
other: in-house data
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Qualifier:
equivalent or similar to
Guideline:
other: ASTM D 445-88
Principles of method if other than guideline:
The time is measured in seconds for a fixed volume of liquid to flow under gravity through the capillary of a calibrated viscometer tube under a reproducible driving head and at a closely control-led temperature. The kinematic viscosity is the product of the measured flow time and the calibration constant of the viscometer tube.
GLP compliance:
not specified
Type of method:
capillary viscometer (static)
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
15

none

Conclusions:
The kinematic viscosity of Reaction products of monoethanolamine and boric acid 1:1 in an ASTM D 115-88 study at 20°C is 15 mm²/s (static).
Executive summary:

viscosity 15 mm²/s (static)

Description of key information

The kinematic viscosity of Reaction products of monoethanolamine and boric acid 1:1 in an ASTM D 115-88 study at 20°C is 15 mm²/s (static).

Key value for chemical safety assessment

Viscosity:
15 mm²/s (static)
at the temperature of:
20 °C

Additional information