Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Acceptable, well-documented study report which meets basic scientific principles, no GLP lab.
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D 93
GLP compliance:
no
Remarks:
Non GLP certified lab
Type of method:
closed cup
Flash point:
77 °C
Atm. press.:
1 atm
Conclusions:
The measured flash point was 77°C at 1 atm using ASTM D 93.
Executive summary:

The measured flash point was 77°C at 1 atm using ASTM D 93.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2006
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Remarks:
Acceptable, well-documented study report which meets basic scientific principles.
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D-93
GLP compliance:
no
Remarks:
Non GLP certified lab
Type of method:
closed cup
Flash point:
73 °C
Atm. press.:
1 atm
Conclusions:
The flash point was 73°C at 1 atm using test method ASTM D-93.
Executive summary:

The flash point was 73°C at 1 atm using test method ASTM D-93.

Endpoint:
flash point of flammable liquids
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Justification for type of information:
The registration substance Hydrocarbons, C11-C14, n-alkanes, isoalkanes, <2% aromatics, EC number 701-280-3 (target) and the test substance Hydrocarbons, C11-C14, n-alkanes, isoalkanes, cyclics, <2% aromatics (source) are both hydrocarbons with many constituents in common.
The source substance covers the carbon number range of the target substance. The substances therefore have qualitatively similar properties (RAAF Scenario 2 applies).
Reason / purpose for cross-reference:
read-across source
Reason / purpose for cross-reference:
read-across source
Flash point:
>= 73 - <= 77 °C
Atm. press.:
1 atm

Description of key information

The flash point is between 73°C and 77°C according to the ASTM D 93 testing methodology, based on data for Hydrocarbons, C11-C14, n-alkanes, isoalkanes, cyclics, <2% aromatics.

Key value for chemical safety assessment

Additional information

The flash point of Hydrocarbons, C11-C14, n-alkanes, isoalkanes, cyclics, <2% aromatics is between 73°C and 77°C according to the ASTM D 93 testing methodology, based on data from two studies. These studies are considered reliable and are used as read-across data for Hydrocarbons, C11-C14, n-alkanes, isoalkanes, <2% aromatics.