Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 July 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Date of Inspection: 21 August 2018, Date of Issue: 19 November 2018
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Remarks:
Setaflash 30000-0 flash point tester
Key result
Flash point:
> 300 °C
Remarks on result:
other: atmospheric pressure not reported

Results of the flash point determination are shown in the following table:

Table 1

Temperature (°C)

Observations

20.0

No flash

25.0

No flash

30.0

No flash

35.0

No flash

40.0

No flash

45.0

No flash

50.0

No flash

55.0

No flash

60.0

No flash

65.0

No flash

70.0

No flash

70.0 (fresh sample)

No flash

75.0

No flash

80.0

No flash

85.0

No flash

90.0

No flash

95.0

No flash

100.0

No flash

105.0 (fresh sample)

No flash

110.0

No flash

115.0

No flash

120.0

No flash

125.0

No flash

130.0

No flash

135.0

No flash

140.0

No flash

150.0

No flash

155.0

No flash

155.0 (fresh sample)

No flash

160.0

No flash

165.0

No flash

170.0

No flash

175.0

No flash

180.0

No flash

185.0

No flash

190.0

No flash

195.0

No flash

200.0

No flash

205.0

No flash

205.0 (fresh sample)

No flash

210.0

No flash

215.0

No flash

220.0

No flash

225.0

No flash

230.0

No flash

235.0

No flash

240.0

No flash

245.0

No flash

250.0

No flash

255.0

No flash

255.0 (fresh sample)

No flash

260.0

No flash

265.0

No flash

270.0

No flash

275.0

No flash

280.0

No flash

285.0

No flash

290.0

No flash

295.0

No flash

300.0

No flash

300.0 (fresh sample)

No flash

Interpretation of results:
GHS criteria not met
Conclusions:
The test item has been determined not to have a flash point below 300°C.
Executive summary:

The test item was determined not to have a flash point below 300°C, using a Setaflash 30000 -0 closed cup flash point tester using a procedure designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Although the substance is a solid, since it is considered as a low melting point solid (melting point <160°C), it was necessary to conduct the flash point test.

Description of key information

> 300°C; EU Method A.9; Tremain, S. P. (2019)

Key value for chemical safety assessment

Additional information

Although the substance is a solid, since it is considered as a low melting point solid (melting point <160°C), it was necessary to conduct the flash point test.