Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: If exposure to vapour, mists or fumes causes drowsiness,

headache, blurred vision or irritation, remove immediately

to fresh air. Keep patient warm and at rest. If any symptoms

persist obtain medical advice.

Emergency measure - Eyes: Immediately flush eyes with copious amounts of water for at

least fifteen minutes. Obtain medical attention if

irritation occurs.

Emergency measure - Skin: Remove contaminated clothing. Wash thoroughly with soap and

water. Obtain medical attention if irritation occurs.

Emergency measure - Ingestion: Obtain immediate medical attention.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxide, dry chemical, alcohol foam or water fog.

Product arising from burning: Oxides of carbon.

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing

apparatus must be worn.

Fight the fire from a safe distance or protected location.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.

Wear appropriate personal protective equipment conforming to

the relevant national or international standards.

Clean the spillage area with detergent and water. For large

spills, dike spilled material or otherwise contain the

material to ensure run-off does not reach a waterway.

Dispose of waste material in accordance with local

regulations by incineration. Containers filled with waste

material must be labelled in the same way as the original

substance containers.

Handling and storage

Handling: The substance should be stored, handled and used under

conditions of good industrial hygiene and in conformity with

any local regulations in order to avoid exposure.

Engineering controls are necessary to reduce exposure to the

substance.

When exposure cannot be prevented or adequately controlled

appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate

international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical protective clothing to Standard EN368

Eye protection to Standard EN166.

Furthermore, when respiratory protective equipment has to be

used, it must be capable of adequately controlling

exposure, be suitable for the purpose, and conform to the

appropriate international or national standards.

These measures should be regarded as a minimum.

Storage: Store in a segregated and approved area in containers

designed for use.

Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: Substance/ Finished lubricants: Marine bulk tanks and

isotanks, drums and containers (500ml to 5 litres).

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: None
Transport: Avoid crushing the containers. In the event of a spillage,
observe the warning labels on the container.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion: Not applicable.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will be minimal. Recovery from

minor spillages or accidental discharge is not economically

or technically feasible, and such waste material will be

disposed of by incineration or landfill. In principle, it

may be possible to recover larger spillages of

uncontaminated material for subsequent use.

Industry - Possibility of neutralisation: The notification tests have shown that the substance is not

classified as 'dangerous'.

Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of solutions mixed

with inert material (eg. sand or soil) may be disposed of by

landfill at an authorised tip in accordance with local

regulations.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning

under controlled conditions at a licensed waste treatment

processor in accordance with local regulations. Stack gases

should be scrubbed, because noxious fumes (eg. carbon

oxides) could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly

to the sewage system or the aqueous environment. However,

adverse effects on sewage treatment systems would be

unlikely.

Industry - Possibility of destruction - other: None.

Public at large - Possibility of recovery/recycling: Disposal via a local waste oil collection point is

recommended.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not recommended by the general public.

Public at large - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of destruction - others: None.