EC number: 211-792-4 | CAS number: 696-29-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
General advice: Take off all contaminated clothing immediately. If you feel unwell, seek medical advice (show the label where possible).
If inhaled: Remove from exposure, lie down. If breathing is irregular or stopped, administer artificial respiration. Monitor breathing, give oxygen if necessary. Consult a physician.
In case of skin contact: Wash off with plenty of water.
In case of eye contact: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed: If swallowed, seek medical advice immediately and show this container or label. If swallowed, DO NOT induce vomiting.
Fire-fighting measures
Extinguishing media
Suitable extinguishing media: Water spray, Dry powder, Foam, Carbon dioxide (CO2)
Special hazards arising from the substance or mixture
Specific hazards during firefighting: Dangerous gases or fumes may occur in case of fire.
Advice for firefighters
Special protective equipment for firefighters: Wear self contained breathing apparatus for fire fighting if necessary.
Further information: Standard procedure for chemical fires. Use water spray to cool unopened containers.
Accidental release measures
Personal precautions, protective equipment and emergency procedures
Use personal protective equipment.
Environmental precautions
Avoid subsoil penetration.
Do not flush into surface water or sanitary sewer system.
Methods and materials for containment and cleaning up
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).
Handling and storage
Precautions for safe handling
Advice on safe handling: Wear personal protective equipment. Avoid contact with skin and eyes.
Advice on protection against fire and explosion: Keep away from open flames, hot surfaces and sources of ignition. Normal measures for preventive fire protection.
Fire-fighting class B: Fires involving liquids or liquid containing substances. Also includes substances which become liquid at elevated temperatures.
Conditions for safe storage, including any incompatibilities
Requirements for storage areas and containers: Store in original container. Keep container tightly closed.
Storage class (TRGS 510) 3: Flammable Liquids
Other data: Stable at normal ambient temperature and pressure.
Container material: suitable materials: Steel
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- 1993
Shippingopen allclose all
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- 1993
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- 1993
Shipping information
- Proper shipping name and description:
- FLAMMABLE LIQUID, N.O.S (Isopropylcyclohexane)
- Chemical name:
- isopropylcyclohexane
- Labels:
- 3
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- 1993
Shipping information
- Proper shipping name and description:
- FLAMMABLE LIQUID, N.O.S (Isopropylcyclohexane)
- Chemical name:
- isopropylcyclohexane
- Labels:
- 3
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Personal protection equipment:
Respiratory protection:
No personal respiratory protective equipment normally required. In inadequately ventilated areas, where workplace limits are exceeded, where unpleasant odours exist or where aerosols are in use, or smoke and mist occur, use self-contained breathing apparatus or breathing apparatus with a type A filter or appropriate combined filter (e.g. where aerosols are in use, or smoke and mist occur, A-P2 or ABEK-P2), in compliance with EN 141.
Hand protection:
The choice of an appropriate glove does not only depend on its material but also on other quality features and is different from one producer to the other., Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time., Be aware that in daily use the durability of a chemical resistant protective glove can be notably shorter than the break through time measured according to EN 374, due to the numerous outside infl ences (e.g. temperature).
Gloves suitable for permanent contact:
Material: Fluorinated rubber
Break through time: >= 480 min
Material thickness: 0.4 mm
Material: Nitrile rubber/nitrile latex
Break through time: >= 480 min
Material thickness: 0.35 mm
Unsuitable gloves: Natural rubber/natural latex, Polychloroprene, butyl-rubber
Eye protection: Tightly fitting safety goggles
Protective measures: Avoid contact with eyes. Wear suitable gloves and eye/face protection.
Stability and reactivity
Reactivity: Stable under recommended storage conditions.
Chemical stability: Stable under normal conditions.
Possibility of hazardous reactions: Heating can release hazardous gases. Vapours may form explosive mixture with air.
Conditions to avoid: Direct heating, dirt, chemical contamination, sunlight, UV or ionising radiation.
Incompatible materials to avoid: Strong oxidizing agents;
Hazardous decomposition products: No decomposition if stored normally.
Disposal considerations
With respect to local regulations, e.g. dispose of to suitable waste incineration plant.
No waste key number as per the European Waste Types List can be assigned to this product, since such classification is based on the
(as yet undetermined) use to which the product is put by the consumer.
The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in
cooperation with the disposal firm / producing firm / official authority.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.