Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Description of key information

Irritation corrosion was studied in vitro in GLP compliant OECD 439 and OECD 492 assays. Both assays were negative.

Key value for chemical safety assessment

Skin irritation / corrosion

Link to relevant study records
Reference
Endpoint:
skin irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 22, 2016 - January 25, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
Version / remarks:
July 26, 2013
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: Council Regulation (EC) No. 440/2008 laying down test methods pursuant to Regulation (EC) No. 1907/2006. B.40.bis. In vitro skin corrosion: human skin model test
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Cell source:
foreskin from a single donor
Justification for test system used:
standard model
Vehicle:
unchanged (no vehicle)
Remarks:
No vehicle used in this study; The test item was applied neat to the tissues.
Details on test system:
CELL CULTURE
- Supplier: EpiSkin/SkinEthic Laboratories, Lyon, France)
- Source: human keratinocytes cultured on a polycarbonate filter in conditions which permit their terminal differentiation
- Format: 24 well plate
- Batch: 16-RHE-127
- Expires: Dec 12, 2016

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment: room temperature
- Temperature of post-treatment incubation: 37°C

REMOVAL OF THE TEST MATERIAL AND CONTROL
At the end of the exposure periods, the test item, positive and negative control was removed immediately by gently rinsing with a minimum volume of 20 mL DPBS using a pipette. Excess DPBS was removed by gently shaking the tissue inserts and blotting the bottom of the tissue inserts with blotting paper.

Control samples:
yes, concurrent negative control
Amount/concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 20 mg ± 3 mg of solid test material
- Concentration (if solution): n/a

VEHICLE
- Amount(s) applied (volume or weight with unit): n/a
- Concentration (if solution): n/a
- Lot/batch no. (if required): n/a
- Purity: n/a

NEGATIVE CONTROL
- Amount(s) applied (volume or weight): 40 µL ± 3 µl (deionised water )
- Concentration (if solution): n/a

POSITIVE CONTROL
- Amount(s) applied (volume or weight): 40 µL ± 3 µl
- Concentration (if solution): A dodecyl sulfate sodium salt solution dissolved deionised water pure was used as positive control.
Duration of treatment / exposure:
42 min
Number of replicates:
3
Controls:
yes, concurrent negative control
Amount / concentration applied:
16 mg
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
Mean relative viability in %
Value:
103.48
Vehicle controls validity:
not applicable
Remarks:
The test item was applied neat to the tissues
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Other effects / acceptance of results:
OTHER EFFECTS:
- Visible damage on test system: none
- Direct-MTT reduction: none
- Colour interference with MTT: none

ACCEPTANCE OF RESULTS:


-Acceptability of the Quality Control Data of the Skin Model with Reference to Historical Batch Data:
The negative control OD values were 1.820, 1.782 and 1.842 and, thus, in the range of ≥0.8 and ≤3.0.

-Acceptability of the Positive and Negative Control:
After treatment with the positive control (5% aqueous solution of sodium dodecyl sulfate) the mean viability value was 1.53% (standard deviation: 8.38%) and, thus, lower than the historically established threshold of 3.10%. After treatment with the negative control (DPBS-buffer) the mean OD was 1.814 (standard deviation: 1.67%) and, thus, higher than the historically established threshold of 1.442.


-Test Substance Data Acceptance Criteria:
The standard deviation between the three tissues replicates treated with the test item was 0.76% and, thus, ≤18%.
The standard deviations between the three tissue replicates of the negative control and the positive control were 1.67% and 8.38%, respectively, and, thus, ≤18%.

The study met all acceptance criteria.





 Group Time / [min]  Mean OD  Mean Relative viability / [%]
 Negative Control 42 1.814 100.00 

 Positive Control

42

0.028

1.53

 Test Material 42 1.877 103.48
Interpretation of results:
GHS criteria not met
Remarks:
Non-corrosive
Conclusions:
This study was performed according to GLP and the methods applied are fully compliant with OECD TG 439. Under the conditions of the present study, the test item is not considered to be irritant to skin.
Executive summary:

This study was performed according to GLP and the methods applied are fully compliant with OECD TG 439.Under the conditions of the present study, the test item is not considered to be irritant to skin.

Endpoint conclusion
Endpoint conclusion:
no adverse effect observed (not irritating)

Eye irritation

Link to relevant study records
Reference
Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Jul 30 - Sep 09, 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 492 (Reconstructed Human Cornea-like Epithelium (RhCE) Test Method for Identifying Chemicals Not Requiring Classification and Labelling for Eye Irritation or Serious Eye Damage)
Version / remarks:
October 9, 2017
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: DB-ALM Protocol No. 164: Ocular Irritation Assay for Chemicals using EpiOcular™ EIT,
Version / remarks:
September 14, 2015
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: EpiOcular Eye Irritation Test (OCL-200-EIT) for the prediction of acute ocular irritation of chemicals; For use with MatTek Corporation`s Reconstructed Human EpiOcular Model; MatTek Corporation
Version / remarks:
June 29, 2015
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: Before application, the test item was pre-warmed to 37°C to get a liquid, which was applied neat to the tissues..
Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent positive control
yes, concurrent negative control
Amount / concentration applied:
TEST MATERIAL: 50 µL per tissue

NEGATIVE / VEHICLE CONTROL: 50 µL per tissue

Sterile deionized water was used as negative control.


POSITIVE CONTROL: 50 µL per tissue

Designation: Methyl acetate
Supplier: Merck KGaA
Lot-No.: S7451611
Catalog #: 8.09711
Purity (GC): 99.6%
Appearance: Liquid
Expiration date: June 30, 2022
Storage: 15 to 25°C

Duration of treatment / exposure:
30 ± 2 minutes
Number of animals or in vitro replicates:
in vitro: duplicate design
Irritation parameter:
other: Viability %
Run / experiment:
Run 1 / Experiment 1
Value:
76.2
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Other effects / acceptance of results:
OTHER EFFECTS:
- Visible damage on test system: No observations

ACCEPTANCE OF RESULTS:
1. The negative control OD is >0.8 and <2.5 (2.086 and 2.183).
2. The mean relative viability of the positive control is below 50% of the negative control viability (13.1%).
3. The difference of viability between the two relating tissues of a single chemical is <20% (values between 0.6% to 6.3%) in the same run (for positive and negative control tissues and tissues of single chemicals).

The study met all acceptance criteria

   Mean OD  Mean Viability
 Negative Control 2.135 100.0% 
 Positive Control 0.280 13.1%
 Test Item 1.626 76.2%
Interpretation of results:
GHS criteria not met
Conclusions:
Under the conditions of the present study, the test item did not show an eye hazard potential. The test item is identified as not requiring classification and labeling according to UN GHS (No Category).
Executive summary:

This study was performed according to GLP and the methods applied are fully compliant with OECD TG 492. Under the conditions of the present study, the test item did not show an eye hazard potential. The test item is identified as not requiring classification and labeling according to UN GHS (No Category).

Endpoint conclusion
Endpoint conclusion:
no adverse effect observed (not irritating)

Respiratory irritation

Endpoint conclusion
Endpoint conclusion:
no study available

Additional information

Justification for classification or non-classification

Based on the provided information there is no need for classification according to the EU Regulation (EC) No 1272/2008 on Classification, Labelling and Packaging of Substances and Mixtures.