Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
melting point/freezing point
Type of information:
read-across based on grouping of substances (category approach)
Adequacy of study:
key study
Study period:
From September 14, 2017 to February 14, 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
KL2 due to RA
Justification for type of information:
Refer to section 13 of IUCLID for details on the Category justification. The study with the read across substance is considered sufficient to fulfil the information requirements as further explained in the provided endpoint summary.
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
not specified
GLP compliance:
yes
Type of method:
capillary method
Key result
Decomposition:
yes
Decomp. temp.:
ca. 106 °C
Remarks on result:
not determinable

Results:

Decomposition: 106°C

Comments

Suspected decomposition was observed from 106°C (the sample started rising up the tube with the evolution of colourless gas). At 130°C the sample ejected out of the tube. The test was terminated.

Conclusions:
Based on the results of the read across study, the test substance is also expected to decompose before melting.

Executive summary:

A study was conducted to determine the melting point of the read across substance, 'Cocodimonium hydroxypropyl hydrolysed wool' (active: 62.8%), using capillary method with photocell detection according to OECD Guideline 102 and EU Method A.1, in compliance with GLP. During the study, suspected decomposition was observed from 106°C (the sample started rising up the tube with the evolution of colourless gas). At 130°C the sample ejected out of the tube. As a result further testing was stopped. Under the study conditions, melting point of the read across substance could not be determined due to decomposition (Chilworth, 2018). Based on the results of the read across study, the test substance, 'Steardimonium hydroxypropyl hydrolysed wool', is also expected to be decomposed before melting.

Endpoint:
melting point/freezing point
Type of information:
read-across based on grouping of substances (category approach)
Adequacy of study:
key study
Study period:
From September 14, 2017 to February 14, 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
KL2 due to RA
Justification for type of information:
Refer to section 13 of IUCLID for details on the Category justification. The study with the read across substance is considered sufficient to fulfil the information requirements as further explained in the provided endpoint summary.
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
not specified
GLP compliance:
yes
Type of method:
differential scanning calorimetry
Key result
Decomposition:
yes
Decomp. temp.:
ca. 120 °C
Remarks on result:
not determinable

Results:

Table 1: Table of results (Screening Test)

 

Endotherm onset temp. (°C)

Heat of melting (J.g-1)

Exotherm onset temp. (°C)

Heat of decomposition

(J.g-1)

Screening Test

42.18

293.01

197.81

122.54

 

Table 2: Table of results

 

Run B

Run C

Run D

Run E

Endotherm onset temp. (°C)

N/A

N/A

N/A

N/A

Mass of Sample Used (g)

4.37

4.91

4.35

3.59

Start Temperature (°C)

0

0

0

0

Final Temperature (°C)

170

170

170

170

Scan Rate (K/min)

1

1

1

1

 

Comment

Suspected decomposition endotherms observed around 120°C. Brown residues were observed in the sample pans after the tests. A visual analysis was performed to confirm suspicion of decomposition.

Conclusions:
Based on the results of the read across study, the test substance is also expected to be decomposed before melting.
Executive summary:

A study was conducted to determine the melting point of the read across substance, 'Cocodimonium hydroxypropyl hydrolysed wool' (active: 62.8%), using Differential Scanning Calorimetry (DSC), according to OECD Guideline 102 and EU Method A.1, in compliance with GLP. Under the study conditions, the melting point for the read across substance could not be determined due to decomposition (Chilworth, 2018). Based on the results of the read across study, the test substance, 'Steardimonium hydroxypropyl hydrolysed wool', is also expected to be decomposed before melting.

Description of key information

Melting point of the read across substance was determined using the differential scanning calorimetery (DSC) and capillary method, according to OECD Guideline 102 and EU Method A.1 (Chilworth, 2018).

Key value for chemical safety assessment

Additional information

Value used for CSA: No melting point could be determined due to decomposition at 106-120°C (based on the results of the read across study)