Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 11 July 2016 and 05 August 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Identification: Benzenesulfonic acid, mono-C10-13-alkyl derivs., compds. with N1,N1-dimethyl-1,3-propanediamine (ACAR 16015)
Appearance/Physical state: Extremely pale amber waxy solid
Batch: 2629-89-10
Purity: 98.6%
Expiry date: 03 April 2019
Storage conditions: Room temperature in the dark
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Preliminary Screening:

The‘rope’failed to ignite during the 2 minutes that the Bunsen flame was applied

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.
Executive summary:

Flammability (Solids).Not highly flammable, using a procedure designed to be compatible with Method A.10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

The test item has been determined not to have a relative self-ignition temperature below its melting temperature

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

Preliminary Screening:

The‘rope’failed to ignite during the 2 minutes that the Bunsen flame was applied

The test item has been determined not to have a relative self-ignition temperature below its melting temperature