Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental Starting Date: 14 June 2016, Experimental Completion Date: 17 June 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
static method
Specific details on test material used for the study:
Batch No.: SC00016331
Appearance: Yellow to brownish yellow liquid
Key result
Temp.:
20 °C
Vapour pressure:
24 hPa
Temp.:
25 °C
Vapour pressure:
32 hPa
Temp.:
50 °C
Vapour pressure:
110 hPa
Conclusions:
The vapour pressure of the test item has been determined to be 24 hPa at 20 ºC, 32 hPa at 25 ºC and 110 hPa at 50 ºC.
Executive summary:

The vapour pressure of Citrathal Concentrate S TW was determined using the static method according to Method A4 Vapour Pressure of Commission Regulation (EC) No 440/2008 and Method 104 of the OECD Guidelines for Testing of Chemicals. The vapour pressure of Citrathal Concentrate S TW is 24 hPa at 20°C.

Description of key information

The vapour pressure of Citrathal Concentrate S TW has been determined to be 24 hPa at 20 °C, using the Static method designed to be compatible with Method A4 Vapour Pressure of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 104 of the OECD Guidelines for Testing of Chemicals, 23 March 2006.

Key value for chemical safety assessment

Vapour pressure:
24 hPa
at the temperature of:
20 °C

Additional information