Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20-22 June 2017
Reliability:
1 (reliable without restriction)
Justification for type of information:
The study was conducted according to an internationally recognised method, and under GLP. The substance is considered to be adequately characterised. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Part I: Classification procedures, test methods and criteria relating to explosives of Class 1
Version / remarks:
UN Handbook “Recommendations on the Transport of Dangerous Goods; Manual of Tests and Criteria”; sixth revised edition, UN, 2015, Section 20.2.1, 20.3.3.3 and Apendix 6 / Screening test
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: OECD Guidelines for the Testing of Chemicals, Method No. 113, adopted 12. May 1981: “Screening Test for Thermal Stability and Stability in Air”
Version / remarks:
1981
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Date of inspection: 13-14 October 2014; Date of signature: 8 April 2015
Key result
Parameter:
other: DSC screening test
Remarks on result:
negative (not further specified)
Remarks:
no significant exothermic event was observed during the DSC run

Calibration :

The measurement of indium after calibration met the validity criteria.

Results of DSC measurement:

Table 4.14.1  Values DSC Test Item

Event

Start of effect [°C]

Energy [J/g]

-

No Event

No Event

Table 4.14.2

   Observations

Mass test item

Mass crucible (before measurement):

Mass crucible (after measurement):

Observations

1.12 mg

617.66 mg

617.37 mg

After the test the crucible was visually unchanged. The crucible was opened, a black residue was observed, the inside sealed gold ring was black discoloured.

Finally, during the DSC run (from 0 to 520 °C) no significant exothermic event was observed.

The measurement of indium after calibration met the validity criteria. Therefore, the result of the study is considered valid.

Interpretation of results:
GHS criteria not met
Conclusions:
A screening via DSC (differential scanning calorimetry) was conducted.
During the DSC run (from 0 to 520 °C) no significant exothermic event was observed. The acceptance procedures for Class 1 explosives need not to be applied.
No additional testing is required. The substance shall not be classified as explosive according to Regulation (EC) N°1272/2008 (CLP).

Executive summary:

The thermal stability of the test substance was tested with Differential Scanning Calorimetry, in accordance with conditions recommended in UN MTC screening procedure/OECD guideline. Up to the maximum test temperature of 520°C, no significant exothermic event was observed.

Description of key information

DSC screening test: no significant exothermic event was observed up to 520°C.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

A fully reliable experimental study, conducted in accordance with conditions recommended in UN MTC screening procedures/OECD guideline, and under GLP, is available. It is considered as a key study. The result is retained as key data.

No further testing is required.

Justification for classification or non-classification

During the DSC run (from 0 to 520 °C) no significant exothermic event was observed. The acceptance procedures for Class 1 explosives need not to be applied.

No additional testing is required. The substance shall not be classified as explosive according to Regulation (EC) N°1272/2008 (CLP).