Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
supporting study
Justification for type of information:
REPORTING FORMAT FOR THE ANALOGUE APPROACH
see "General Justification for Read-Across" attached to IUCLID section 13

1. HYPOTHESIS FOR THE ANALOGUE APPROACH
Mutual read across from the AAPBs to one another is justified:

a) Based on the information given in section 1, it can be concluded that all AAPBs mentioned above are similar in structure, since they are manufactured from similar resp. identical precursors under similar conditions and all contain the same functional groups. Thus a common mode of action can be assumed.
b) The content of minor constituents in all products are comparable and differ to an irrelevant amount.
c) The only deviation within this group of substances is a minor variety in their fatty acid moiety, which is not expected to have a relevant impact on intrinsic toxic or ecotoxic activity and environmental fate. Potential minor impact on specific endpoints will be discussed in the specific endpoint sections.

The read-across hypothesis is based on structural similarity of target and source substances. Based on the available experimental data, including key physico-chemical properties and data from toxicokinetic, acute toxicity, irritation, sensitisation, genotoxicity and repeated dose toxicity studies, the read-across strategy is supported by a quite similar toxicological profile of all five substances.
The respective data are summarised in the data matrix; robust study summaries are included in the Technical Dossier in the respective sections.

2. SOURCE AND TARGET CHEMICAL(S) (INCLUDING INFORMATION ON PURITY AND IMPURITIES)
see "General Justification for Read-Across" attached to IUCLID section 13

3. ANALOGUE APPROACH JUSTIFICATION
see "General Justification for Read-Across" attached to IUCLID section 13

4. DATA MATRIX
see "General Justification for Read-Across" attached to IUCLID section 13
Reason / purpose for cross-reference:
read-across: supporting information
Reason / purpose for cross-reference:
read-across source
Flash point:
> 230 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met

Description of key information

A study on flash point does not need to be conducted. 

Key value for chemical safety assessment

Additional information

According to REACH Annex XI, 1., a test for the determination of the flash point of the substance is scientifically not necessary because the flash point refers to liquids (Reach R7.1.9). The substance is solid at ambient temperature; therefore a determination of the flash point is not required.