Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
03 Oct. - 18 Oct. 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
Qualifier:
according to guideline
Guideline:
DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
Version / remarks:
2003-05
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
4,4,5,5,6,6,7,7,8,8,9,9,9-tridecafluorononyl methacrylate
EC Number:
812-877-4
Cas Number:
1228350-17-1
Molecular formula:
C13 H11 F13 O2
IUPAC Name:
4,4,5,5,6,6,7,7,8,8,9,9,9-tridecafluorononyl methacrylate
Test material form:
liquid
Details on test material:
Test Item name Fluowet PMA600
Batch No. DH213/16
Appearance transparent to brownish liquid
Purity 99.4 %
Expiry date 01 June 2017
Storage room temperature, protected from light
Specific details on test material used for the study:
Batch No. DH213/16
Appearance transparent to brownish liquid
Purity 99.4%
Expiry date 01 June 2017
Storage room temperature, protected from light

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
>= 370 °C
Remarks on result:
other: at ambient atmospheric pressure

Any other information on results incl. tables

Table 1.Determination of Auto-Ignition Temperature of Fluowet PMA600

(A2 measurement on 06 October 2016)

Sample Temperature, °C

Oven Temperature, °C

Ignition delay time, (s)

Sample amount

(drops)

Ignition

381.7

393.3

-

12

-

380.0

392.3

-

8

-

380.2

392.7

-

4

-

381.7

392.7

213

16

+

379.2

390.7

-

16

-

379.0

391.1

-

12

-

378.2

390.3

-

8

-

378.4

390.7

-

4

-

381.0

392.3

-

16

-

380.5

392.5

-

12

-

380.4

392.5

-

8

-

380.2

392.7

-

4

-

382.2

392.1

-

20

-

382.9

394.4

-

16

-

382.7

394.2

-

12

-

382.7

394.2

-

8

-

382.5

394.4

-

4

-

384.5

394.4

-

20

-

385.5

396.4

-

16

-

385.2

396.8

-

12

-

384.5

396.6

-

8

-

384.2

396.4

-

4

-

386.3

396.2

-

20

-

387.7

398.3

239

16

+

384.7

396.4

-

16

-

384.7

396.6

-

12

-

384.3

396.4

-

8

-

384.2

396.4

-

4

-

387.7

398.5

-

16

-

386.8

398.7

-

12

-

386.8

398.9

-

8

-

386.7

399.1

-

4

-

388.8

399.3

-

20

-

390.3

401.4

-

16

-

389.2

400.9

-

12

-

389.0

401.1

-

8

-

388.5

401.1

-

4

-

390.5

401.1

-

20

-

392.1

403.0

-

16

-

391.1

403.0

-

12

-

391.0

403.0

-

8

-

390.8

403.0

-

4

-

392.6

403.2

-

20

-


Table 1.Determination of Auto-Ignition Temperature of Fluowet PMA600 (continued)

(A2 measurement on 06 October 2016)

Sample Temperature, °C

Oven Temperature, °C

Ignition delay time, (s)

Sample amount

(drops)

Ignition

394.1

405.0

-

16

-

393.1

405.0

-

12

-

393.1

405.0

-

8

-

392.6

405.4

-

4

-

394.3

405.0

-

20

-

396.1

407.3

-

16

-

395.3

406.7

-

12

-

394.0

406.7

18

8

+

392.6

404.4

-

8

-

393.0

405.2

-

4

-

393.3

404.8

-

12

-

394.3

405.2

-

16

-

Auto-ignition temperature:

380 °C

 

(explanation: - not ignited, + ignited)

 

 

Table 2.Determination of Auto-Ignition Temperature of Fluowet PMA600

(A2 measurement on 07 October 2016)

Sample Temperature, °C

Oven Temperature, °C

Ignition delay time, (s)

Sample amount

(drops)

Ignition

379.4

392.7

-

12

-

379.4

392.9

-

8

-

379.7

393.3

-

4

-

380.5

393.1

128

16

+

378.6

391.1

-

16

-

378.6

391.5

-

12

-

378.4

391.3

-

8

-

377.6

390.7

-

4

-

379.2

391.1

189

20

+

376.9

388.8

247

20

+

373.6

386.6

8

20

+

372.6

384.7

-

20

-

371.9

385.1

17

16

+

370.1

382.9

-

16

-

370.4

383.3

-

12

-

370.1

383.1

-

8

-

370.1

383.1

-

4

-

372.6

385.3

-

16

-

371.6

384.7

-

12

-

372.1

385.1

-

8

-

371.9

384.9

-

4

-

372.4

384.7

-

20

-


Table 2.Determination of Auto-Ignition Temperature of Fluowet PMA600 (continued)

(A2 measurement on 07 October 2016)

Sample Temperature, °C

Oven Temperature, °C

Ignition delay time, (s)

Sample amount

(drops)

Ignition

374.7

387.6

-

16

-

374.2

387.2

-

12

-

374.4

387.6

-

8

-

374.4

387.4

-

4

-

375.1

387.4

-

20

-

376.6

390.0

8

16

+

374.2

386.8

-

16

-

374.7

387.8

-

12

-

374.6

387.8

6

8

+

372.1

385.1

-

8

-

372.8

385.7

-

4

-

372.4

385.5

-

12

-

372.8

385.3

-

16

-

374.7

387.6

-

8

-

374.1

387.0

-

4

-

374.6

387.4

-

12

-

374.9

387.6

-

16

-

374.1

387.4

19

20

+

372.9

385.1

-

20

-

372.9

385.9

-

16

-

372.6

385.5

-

12

-

372.8

385.7

-

8

-

Auto-ignition temperature:

370 °C

 

(explanation: - not ignited, + ignited)

 

 

Table 3.Determination of Auto-Ignition Temperature of Fluowet PMA600

(A2 measurement on 08 October 2016)

Sample Temperature, °C

Oven Temperature, °C

Ignition delay time, (s)

Sample amount

(drops)

Ignition

381.7

393.6

-

12

-

381.7

393.8

-

8

-

381.2

392.9

4

4

+

378.9

390.3

4

4

+

377.1

388.4

-

4

-

377.6

388.8

-

8

-

377.4

388.6

-

12

-

378.6

388.8

-

16

-

378.9

390.1

-

4

-

378.4

389.8

-

8

-

379.0

390.3

-

12

-

379.2

389.8

-

16

-

380.9

390.1

-

20

-

381.2

393.1

-

4

-


Table 3.Determination of Auto-Ignition Temperature of Fluowet PMA600 (continued)

(A2 measurement on 08 October 2016)

Sample Temperature, °C

Oven Temperature, °C

Ignition delay time, (s)

Sample amount

(drops)

Ignition

380.5

391.7

-

8

-

381.0

392.3

-

12

-

381.5

392.1

-

16

-

383.2

392.1

-

20

-

383.0

394.4

4

4

+

380.5

391.7

-

4

-

381.2

392.5

-

8

-

381.0

391.9

-

12

-

381.4

392.1

-

16

-

383.4

394.6

-

4

-

382.7

394.2

-

8

-

383.0

394.2

-

12

-

382.9

394.4

5

16

+

380.7

392.1

5

16

+

379.0

389.8

-

16

-

379.4

390.3

-

12

-

378.9

390.0

-

8

-

378.9

390.1

-

4

-

Auto-ignition temperature:

375 °C

 

(explanation: - not ignited, + ignited)

Applicant's summary and conclusion

Conclusions:
The lowest ignition temperature was 370 °C in the course of the three main A2 test series.
The auto-ignition temperatureofFluowet PMA600is 370 °C determined as in DIN 51794.
Executive summary:

The auto-ignition temperature as obtained by this method was the minimum ambient temperature expressed in °C at which a certain volume of a substance ignites under the above conditions.

Three replicate main tests were performed under atmospheric pressure.

The lowest ignition temperature was 370 °C in the course of the three main A2 test series.

The auto-ignition temperatureofFluowet PMA600is 370 °C determined as in DIN 51794.