Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Principles of method if other than guideline:
The test method covers the determination of the flash point of petroleum products by a manual Pensky-Martens closed-cup apparatus;
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
133 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: The specification for this end point is > 110°C
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point is 133°C, the substance is not flammable
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Principles of method if other than guideline:
The test method covers the determination of the flash point of petroleum products by a manual Pensky-Martens cloed-cup apparatus;
GLP compliance:
not specified
Type of method:
closed cup
Remarks:
STM D 93 Procedure A
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
138 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: The flash point specification is > 110°C
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point is 138°C, the substance is not flammable

Description of key information

The value of flash point has been determined in-company, following the test method ASTM D93 and confirmed in another laboratory. The obtained values are equal in both laboratories.

The flash point of the substance is well above the value leading to classification.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
133 °C

Additional information