Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

If inhaled:

- Move to fresh air in case of accidental inhalation of fumes from overheating or combustion.

- Oxygen or artificial respiration if needed.

In case of eye contact:

- Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.

In case of skin contact:

- Wash off with plenty of water.

If swallowed:

- Drink 1 or 2 glasses of water.

- Do NOT induce vomiting.

- Consult a physician.

Fire-fighting measures

Suitable extinguishing media:

- Water

- powder

- Foam

- Dry chemical

- Carbon dioxide (CO2)

Unsuitable extinguishing media:

- None.

Special hazards arising from the substance or mixture:

- In case of fire hazardous decomposition products may be produced such as: Gaseous hydrogen fluoride (HF), Fluorophosgene

Advice for firefighters:

- Wear self-contained breathing apparatus and protective suit.

- When intervention in close proximity wear acid resistant over suit.

- Evacuate personnel to safe areas.

- Approach from upwind.

- Protect intervention team with a water spray as they approach the fire.

- Keep containers and surroundings cool with water spray.

- Keep product and empty container away from heat and sources of ignition.

Accidental release measures

Advice for non-emergency personnel:

- Prevent further leakage or spillage if safe to do so.

Advice for emergency responders:

- Ensure adequate ventilation.

- Material can create slippery conditions.

- Sweep up to prevent slipping hazard.

- Keep away from open flames, hot surfaces and sources of ignition.

Environmental precautions:

- Should not be released into the environment.

- Do not flush into surface water or sanitary sewer system.

Methods and materials for containment and cleaning up:

- Soak up with inert absorbent material.

- Suitable material for picking up

- Dry sand

- Earth

- Shovel into suitable container for disposal.

Handling and storage

Precautions for safe handling:


- Ensure adequate ventilation.


- Use personal protective equipment.


- Keep away from heat and sources of ignition.


- To avoid thermal decomposition, do not overheat.


 


Conditions for storage, including incompatibilities


Storage:


- Store in a well-ventilated place.


- Keep away from heat and sources of ignition.


- Keep in properly labelled containers.


- Keep away from combustible material.


- Keep away from incompatible products


- Provide tight electrical equipment well protected against corrosion.


- Refer to protective measures.


 


Packaging material


Suitable material:


- Plastic material

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
None. The substance does not meet the classification criteria for transport.
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
None. The substance does not meet the classification criteria for transport.
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
None. The substance does not meet the classification criteria for transport.
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
None. The substance does not meet the classification criteria for transport.
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Appropriate engineering controls:


- Provide local ventilation appropriate to the product decomposition risk (see section 10).


- Refer to protective measures listed in sections 7 and 8.


- Apply technical measures to comply with the occupational exposure limits.


 


Individual protection measures:


1. Respiratory protection:


- In case of insufficient ventilation, wear suitable respiratory equipment.
- In case of vapour or mist, face mask with combined ABEK-P3 cartridge.
- Respiratory protection complying with EN 141.
- In case of decomposition, use an air breathing apparatus with face mask.
- Self-contained open-circuit compressed air breathing apparatus (EN 137)
- Self-contained closed-circuit breathing apparatus compressed (EN 145)


2. Hand protection:


- Protective gloves complying with EN 374.


- Nitrile rubber
- Neoprene gloves


- Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact).


3. Eye protection:


- Tightly fitting safety goggles, eye protection according to EN 166


4. Skin and body protection:


- work overall and safety shoes


5. Hygiene measures:


- Ensure that eyewash stations and safety showers are close to the workstation location.


- When using do not eat, drink or smoke.


- Wash hands before breaks and at the end of workday.


- Handle in accordance with good industrial hygiene and safety practice.


 


Environmental exposure controls


- Dispose of rinse water in accordance with local and national regulations.

Stability and reactivity

Reactivity:


- No dangerous reaction known under conditions of normal use.


Chemical stability:


- Stable under recommended storage conditions.


Possibility of hazardous reactions:


- No dangerous reaction known under conditions of normal use.


Conditions to avoid:


- Insufficient ventilation


- To avoid thermal decomposition, do not overheat.


Incompatible materials:


- Bases


Hazardous decomposition products:


- Gaseous hydrogen fluoride (HF), Carbon dioxide (CO2), Gaseous hydrogen chloride (HCl), Carbon monoxide

Disposal considerations

Waste treatment methods:

- Dispose of in accordance with local regulations.

Contaminated packaging:

- Empty containers can be landfilled, when in accordance with the local regulations.